{"product_id":"ic200udr164-ge-fanuc-versamax-micro-controller","title":"IC200UDR164 GE Fanuc VersaMax Micro Controller","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200UDR164\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200UDR164\u003c\/strong\u003e Micro Controller, operates as a dedicated hardware component for direct signal processing and control loop execution within VersaMax system networks. The unit integrates 40 discrete AC\/DC inputs and 24 normally open SPST relay outputs on board, managing 64 total I\/O points across the local processing unit.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UDR164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.00 lbs (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact VersaMax Micro footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC input voltage range (50-60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard I\/O Points\u003c\/td\u003e\n\u003ctd\u003e64 points (40 Inputs \/ 24 Outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eNormally Open Relay Outputs (SPST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e2 A maximum resistive load at 24 VDC and 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Logic\u003c\/td\u003e\n\u003ctd\u003eConfigurable positive or negative logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoldup Time\u003c\/td\u003e\n\u003ctd\u003e10 ms at 85-100 VAC; 20 ms at 100-265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A at 200 VAC; 40 A at 265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe microcontroller unit coordinates data transfers across internal expansion buses to execute local logic cycles and manage field device signals. High-density I\/O handling is maintained via 40 input circuits supporting selectable positive or negative logic polarities. Firmware flash compatibility within the unit ensures real-time synchronicity during execution cycles, maintaining system data integrity during brief line power disruptions via onboard holdup capacitors rated up to 20 ms at nominal operating voltages.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the contact output specs and limits for the IC200UDR164?\u003c\/p\u003e\n\u003cp\u003eA: The onboard output section provides 24 SPST normally open relay contacts, rated for a maximum resistive load of 2 A per channel at either 24 VDC or 240 VAC.\u003c\/p\u003e\n\u003cp\u003eQ: What input power source is required to operate the microcontroller?\u003c\/p\u003e\n\u003cp\u003eA: The module operates directly from an AC line voltage ranging from 100 VAC to 240 VAC at 50 to 60 Hz.\u003c\/p\u003e\n\u003cp\u003eQ: How long can the unit maintain operation during an AC mains voltage dip?\u003c\/p\u003e\n\u003cp\u003eA: The internal power supply provides a holdup time of 10 ms for line voltages between 85-100 VAC and up to 20 ms for voltages between 100-265 VAC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the unit securely onto a standard 35 mm DIN rail or fasten it directly to an electrical enclosure backpanel using mounting hardware.\u003c\/li\u003e\n\u003cli\u003eWire incoming AC supply lines (100-240 VAC) to the dedicated line, neutral, and ground input terminals.\u003c\/li\u003e\n\u003cli\u003eEnsure inductive field loads connected to the relay output channels feature proper RC snubbers or flyback diodes to prevent arc erosion on the SPST contacts.\u003c\/li\u003e\n\u003cli\u003eGround the controller frame to the main enclosure earth ground terminal using heavy-gauge copper conductor.\u003c\/li\u003e\n\u003cli\u003eVerify that inrush current limits are accounted for in power distribution protection design (up to 40 A at 265 VAC).\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43796931313754,"sku":"IC200UDR164","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200UDR164.jpg?v=1786092980","url":"https:\/\/www.spareoil.com\/es\/products\/ic200udr164-ge-fanuc-versamax-micro-controller","provider":"SpareOil Automation","version":"1.0","type":"link"}