{"product_id":"ic693cbl303-ge-fanucseries-90-30-programming-cable","title":"IC693CBL303 GE FanucSeries 90-30 Programming Cable","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693CBL303\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693CBL303\u003c\/strong\u003e Hand-Held Programmer Cable, operates as a dedicated hardware component for serial communications and power delivery within GE Fanuc Series 90-30 PLC systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CBL303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lbs (0.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 2 m length cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive bus-powered link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eBelden 9508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e24 AWG (0.22 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e6 feet (2 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eCanon DA15S 15-pin D-subminiature male (both ends)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHood Assembly\u003c\/td\u003e\n\u003ctd\u003eAMP 207470-1 connector shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Kit\u003c\/td\u003e\n\u003ctd\u003eAMP 207871-1 (2 metric screws and 2 screw clips)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Protocol\u003c\/td\u003e\n\u003ctd\u003eRS-485 serial point-to-point \/ HHP detection signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe IC693CBL303 maintains deterministic serial links between the IC693PRG300 Hand-Held Programmer (HHP) and the 15-pin D-sub serial port integrated into the Series 90-30 PLC power supply unit. Beyond signal transmission for firmware programming and status monitoring, the internal conductor arrangement routes supply power directly to the HHP terminal. The physical pinout carries a dedicated loopback status signal indicating positive connection verification to the processing unit, maintaining real-time communication velocity and system diagnostics across the backplane network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC693CBL303 cable be extended beyond its standard 2-meter length?\u003c\/p\u003e\n\u003cp\u003eA: Extensions are not recommended without proper impedance matching. Custom extension lengths increase loop capacitance and exposure to electromagnetic interference, which degrades signal integrity across the RS-485 serial interface.\u003c\/p\u003e\n\u003cp\u003eQ: How does the PLC detect that the Hand-Held Programmer is connected via this cable?\u003c\/p\u003e\n\u003cp\u003eA: The cable assembly features an internal signal connection integrated into the 15-pin connector array. When mated to the power supply serial port, this dedicated pin set completes a detection loop that alerts the PLC CPU of an active hardware interface.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IC693CBL303 require an external power supply to operate the attached terminal?\u003c\/p\u003e\n\u003cp\u003eA: No. The cable routes 5 VDC power directly from the Series 90-30 power supply serial port pins to the hand-held programming unit alongside data lines.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the controller frame or verify local safety clearance prior to connecting hardware terminals to avoid transient electrical arcing on the port pins.\u003c\/li\u003e\n\u003cli\u003eAlign the 15-pin male DA15S D-subminiature connector with the serial port located on the GE Fanuc Series 90-30 PLC power supply module.\u003c\/li\u003e\n\u003cli\u003eFully seat the connector shell and tighten the two AMP metric jack-screws to 0.4 Nm using a calibrated screwdriver to ensure continuous chassis grounding and strain relief.\u003c\/li\u003e\n\u003cli\u003eRoute the 24 AWG Belden 9508 cable clear of high-voltage AC conductors, motor leads, and variable frequency drive outputs to prevent noise coupling.\u003c\/li\u003e\n\u003cli\u003eConnect the remaining 15-pin male D-sub end to the IC693PRG300 Hand-Held Programmer terminal and secure the mounting hardware before initiating system communication.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43778181759066,"sku":"IC693CBL303","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693CBL3031.png?v=1785727281","url":"https:\/\/www.spareoil.com\/es\/products\/ic693cbl303-ge-fanucseries-90-30-programming-cable","provider":"SpareOil Automation","version":"1.0","type":"link"}