{"product_id":"ic693cmm302-ge-series-90-30-genius-communication-module","title":"IC693CMM302 GE Series 90-30 Genius Communication Module","description":"\u003cp\u003eConfigured for Genius network connectivity in Series 90-30 Programmable Logic Controller (PLC) architectures, the \u003cstrong\u003eGE IC693CMM302\u003c\/strong\u003e (\u003cstrong\u003eIC693CMM302\u003c\/strong\u003e Enhanced Genius Communications Module) provides direct physical\/electrical execution of global data exchange across a dedicated industrial bus. The hardware occupies a single backplane slot to route data between the host controller and remote network nodes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CMM302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.40 kg (0.88 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.5 W (\u0026lt; 300 mA @ 5 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Bus Devices\u003c\/td\u003e\n\u003ctd\u003e31 devices per module (up to 62 per controller)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Data Capacity\u003c\/td\u003e\n\u003ctd\u003e128 bytes transmit \/ 128 bytes receive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported PLC Registers\u003c\/td\u003e\n\u003ctd\u003e%G, %I, %Q, %AI, %AQ, %R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eModule OK LED, COMM LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e0.2-inch displacement (5-10 Hz), 1 G (10-200 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Shock\u003c\/td\u003e\n\u003ctd\u003e5 G for 10 ms duration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe IC693CMM302 utilizes specific firmware flash compatibility to interface with host processor register tables, facilitating deterministic synchronization of global data. By establishing dedicated bus topologies independent of standard backplane traffic, the module maximizes overall I\/O density scaling. The data structure maps directly into discrete and analog allocation zones, maintaining rigid scan-time intervals without inducing processor calculation jitter during multipoint broadcast cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC693CMM302 operate within the same rack alongside standard legacy GCM modules?\u003c\/p\u003e\n\u003cp\u003eA: No. The IC693CMM302 is an enhanced GCM+ device and cannot be mixed with standard legacy Genius Communication Modules (GCM) within the same host PLC configuration.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane location constraints when installing the module?\u003c\/p\u003e\n\u003cp\u003eA: The module can be installed in any available I\/O slot on CPU baseplates, expansion baseplates, or remote baseplates. It must not be inserted into the dedicated CPU slot.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Topology Termination:\u003c\/strong\u003e Implement correct electrical termination at both physical ends of the Genius bus cable. Use designated termination resistors matching the characteristic impedance of the trunk cable to prevent signal reflections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Protocols:\u003c\/strong\u003e Strip back cable insulation at the module connector and connect the shield wire to the specified chassis ground point. Maintain shield continuity across all tap blocks without creating loops to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal and Environmental Conditions:\u003c\/strong\u003e Verify that ambient panel temperature stays between 0 and +60 deg C. Provide continuous airflow if the module is mounted in a high-density enclosure with non-condensing relative humidity between 5% and 95%.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43623305183322,"sku":"IC693CMM302","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC693CMM302.png?v=1783564084","url":"https:\/\/www.spareoil.com\/es\/products\/ic693cmm302-ge-series-90-30-genius-communication-module","provider":"SpareOil Automation","version":"1.0","type":"link"}