{"product_id":"ic695alg112-ge-fanuc-pacsystems-rx3i-analog-input-module","title":"IC695ALG112 GE Fanuc PACSystems RX3i Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695ALG112\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695ALG112\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for converting analog process signals into digital data records within PACSystems RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.81 lbs (0.37 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot RX3i module profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.89 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e8 single-ended input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003eVoltage: 0 to 10 VDC, -10 to +10 VDC, +\/-5 VDC, 0 to 5 VDC, 1 to 5 VDC; Current: 0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADC Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% of range at 25 deg C; 0.2% over full temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Data Format\u003c\/td\u003e\n\u003ctd\u003eConfigurable as IEEE 32-bit floating point or 16-bit integer in a 32-bit field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Low-Pass Filters\u003c\/td\u003e\n\u003ctd\u003e8 Hz, 12 Hz, 16 Hz, 40 Hz, 250 Hz, 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;500 kOhm (Voltage mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Protection Limits\u003c\/td\u003e\n\u003ctd\u003eOvervoltage: +\/-35 VDC; Overcurrent: +\/-35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Predictive Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe IC695ALG112 maximizes backplane bus communication velocity across RX3i backplane architectures, transferring 16-bit converted analog data directly to CPU memory tables without scan-time degradation. Integrated predictive diagnostic routines execute continuous error checking during initial startup and runtime operation to verify channel integrity. Full firmware flash compatibility allows field-upgrades of module flash memory, ensuring seamless integration with deterministically scaled I\/O layouts and software-configurable parameter tables without hardware jumper settings.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC695ALG112 analog input module require hardware jumpers for input range selection?\u003c\/p\u003e\n\u003cp\u003eA: No. The IC695ALG112 is entirely software-configurable through Proficy Machine Edition, eliminating the need for physical jumper switches when setting voltage or current ranges.\u003c\/p\u003e\n\u003cp\u003eQ: How do the software-configurable digital filters impact channel step-response settling time?\u003c\/p\u003e\n\u003cp\u003eA: The step-response settling time to 0.1% of final value varies by selected filter frequency: 127 ms at 8 Hz, 67 ms at 12 Hz, 56 ms at 16 Hz, 21 ms at 40 Hz, 3.1 ms at 250 Hz, and 1.7 ms at 1000 Hz.\u003c\/p\u003e\n\u003cp\u003eQ: What is the open-circuit detection threshold when a signal wire breaks on a 4-20 mA loop?\u003c\/p\u003e\n\u003cp\u003eA: The module executes open-circuit detection with a maximum response time of 1 second, raising channel fault flags to the RX3i CPU.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eShut off backplane power to the PACSystems RX3i chassis before inserting or extracting the IC695ALG112 module.\u003c\/li\u003e\n\u003cli\u003eAlign the module housing with the card guide rails of the target RX3i backplane slot and press firmly until the rear backplane connectors engage.\u003c\/li\u003e\n\u003cli\u003eWire signal transmitters using shielded twisted-pair cabling to minimize industrial electromagnetic noise coupling.\u003c\/li\u003e\n\u003cli\u003eConnect cable drain wires to the designated system shield ground bus at one end only to prevent ground loop currents across the analog circuit.\u003c\/li\u003e\n\u003cli\u003eApply power and download the hardware configuration file from Proficy Machine Edition to establish channel range types, filter frequencies, and reporting formats.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43778242052186,"sku":"IC695ALG112","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC695ALG112.png?v=1785736472","url":"https:\/\/www.spareoil.com\/es\/products\/ic695alg112-ge-fanuc-pacsystems-rx3i-analog-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}