{"product_id":"mx6-a-yokogawa-centum-vp-analog-i-o-module-s9840bp-05","title":"MX6*A Yokogawa CENTUM VP Analog I\/O Module S9840BP-05","description":"\u003ch2\u003eYOKOGAWA MX6*A INTERFACE MODULE CARD\u003c\/h2\u003e\n\u003cp\u003eConfigured for Specific Technical Task in System\/Network Name, the \u003cstrong\u003eYOKOGAWA MX6*A\u003c\/strong\u003e (\u003cstrong\u003eMX6-A\u003c\/strong\u003e Analog I\/O Module) provides direct physical\/electrical execution. This hardware component interfaces directly with field transmitters, sensors, and actuators to process high-density analog signals while maintaining structural isolation from the core backplane logic. The module supports point-to-point operational monitoring via integrated diagnostic light-emitting diodes (LEDs) to verify localized loop continuity and operational state transitions without external diagnostic tooling.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMX6*A (MX6-A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 x 25 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number Variant\u003c\/td\u003e\n\u003ctd\u003eS9840BP-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e32 analog I\/O channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC, 1-5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA, 1 to 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC, 1 to 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (channel-to-system, 1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLED indicators for channel ON\/OFF and fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant operation supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack-mounted (FCU slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control \u0026amp; Analog Loop Execution\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA MX6*A\u003c\/strong\u003e utilizes a dedicated 4-20 mA HART loop protocol architecture to govern field communication loops, ensuring deterministic updates across all 32 channels. Channel-to-channel isolation parameters prevent ground loop transients from propagating through the internal field control units (FCU). For thermal and voltage stabilization, the onboard firmware applies cold junction compensation (CJC) algorithms alongside zero-point offset tracking to suppress signal drift across the entire 0 to 60 deg C operational band. The module dynamically manages output impedances to ensure linear actuator positioning and precise sensor conversions down to the +\/-0.1% accuracy threshold.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module execute dual-redundancy switching during a backplane communication fault?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on parallel rail topology inside the FCU slot. When the primary card drops internal heartbeats, the backup module assumes control of the 4-20 mA loop within predefined milliseconds without interrupting output signals to field actuators.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be hot-swapped while the field control unit is powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes, hot-swapping is supported. However, the online replacement sequence requires the user to verify the redundant mate is active and error-free before extracting the faulty module to prevent loop interruption.\u003c\/p\u003e\n\u003cp\u003eQ: What specific fault states trigger the diagnostic LEDs?\u003c\/p\u003e\n\u003cp\u003eA: The hardware diagnostic LEDs change status when detecting open-loop field wiring conditions, short circuits on individual 4-20 mA loops, or an internal hardware failure within the analog-to-digital converter circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Alignment:\u003c\/strong\u003e Insert the module vertically into the designated rack-mounted FCU slot. Ensure the top and bottom locking tabs click into place to maintain reliable electrical connectivity with the backplane bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Terminate all analog signal cable shields at the dedicated marshalling cabinet ground bar. Do not allow multi-point grounding loops to form between the field transmitter chassis and the module rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation:\u003c\/strong\u003e Route low-voltage 4-20 mA and 1-5 VDC signal lines via separate wire ducts, maintaining a distance of at least 300 mm from high-voltage AC power lines to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain unimpeded vertical airflow through the chassis assembly. Verify that total cabinet power consumption does not exceed the ambient heat dissipation rating to keep temperatures below 60 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43668088586330,"sku":"MX6*A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/585.jpg?v=1784258040","url":"https:\/\/www.spareoil.com\/es\/products\/mx6-a-yokogawa-centum-vp-analog-i-o-module-s9840bp-05","provider":"SpareOil Automation","version":"1.0","type":"link"}