{"product_id":"p0916bt-foxboro-termination-assembly-new-original-stock","title":"P0916BT Foxboro Termination Assembly | New \u0026 Original Stock","description":"\u003ch2\u003eFoxboro P0916BT Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0916BT\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eP0916BT\u003c\/strong\u003e Termination Assembly, operates as a dedicated hardware component for field wiring distribution and signal conditioning within Foxboro I\/A Series and Evo DCS platforms. The unit forms the direct physical termination interface for external 4-20 mA current loops routed to the secondary FBM211 analog input module.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0916BT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.61 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 200 Series assembly profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 8.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 independent analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eStandard 4-20 mA current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Termination\u003c\/td\u003e\n\u003ctd\u003eScrew-clamp terminals (12-22 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail with locking mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 (cabinet installation required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e16 MB SDRAM, 32 MB Flash (for local data handling)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and channel-to-ground isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Properties\u003c\/h3\u003e\n\u003cp\u003eThe termination assembly utilizes channel-to-channel isolation parameters to isolate physical field sensor signals from the primary backplane processing logic, preventing common-mode noise propagation. The electrical architecture of the 16 independent channels accommodates the 4-20 mA HART loop protocol, allowing high-frequency digital communication signals to pass unimpeded to the FBM211 subsystem. Cold junction compensation (CJC) biasing circuits are embedded into the substrate layer to stabilize millivolt inputs when encountering thermal variations across the terminal blocks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the FBM211 module connected to this assembly be replaced while the system is under power?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the hot-swappable architecture allows connected Fieldbus Modules to be extracted or inserted without disconnecting the permanent field wiring terminated on the P0916BT block and without interrupting the operational state of the DCS.\u003c\/p\u003e\n\u003cp\u003eQ: What are the cable distance constraints between the field transmitter and the termination assembly?\u003c\/p\u003e\n\u003cp\u003eA: The physical layer supports maximum cable runs up to 1000 m (3280 ft), provided the interconnecting field cable meets standard gauge requirements (12-22 AWG) and incorporates continuous, single-ended shielding.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Snap the assembly onto standard symmetric DIN rails, ensuring the integrated locking mechanism is completely engaged to prevent physical shifting during high-vibration events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Strip field cables and secure the drain wires directly to the master instrumentation ground bar within the enclosure panel. Do not terminate field shields at both the transmitter end and the P0916BT assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Sizing:\u003c\/strong\u003e Strip field wire insulation to specified tolerances and secure into the screw-clamp blocks using 12-22 AWG copper conductors, applying factory-rated torque limits to all terminal screws.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43454277910618,"sku":"P0916BT","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/393._88ec2207-3bdc-4178-8702-a46b2151cfce.jpg?v=1780621331","url":"https:\/\/www.spareoil.com\/es\/products\/p0916bt-foxboro-termination-assembly-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}