{"product_id":"remote-control-i-o-module-yokogawa-rc1-a-centum-vp","title":"Remote Control I\/O Module YOKOGAWA RC1*A CENTUM VP","description":"\u003ch2\u003eYOKOGAWA RC1*A Remote Control I\/O Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for field signal termination and remote control execution in CENTUM VP and CS 3000 DCS platforms, the \u003cstrong\u003eYOKOGAWA RC1*A\u003c\/strong\u003e (\u003cstrong\u003eRC1A\u003c\/strong\u003e Remote I\/O Module) provides direct physical\/electrical execution of sensor-to-controller signal interface management.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRC1\u003c\/strong\u003e: Base model identifier for remote control I\/O functionality and signal interface management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e*A\u003c\/strong\u003e: Hardware revision and interface designation indicating compatibility with standard CENTUM DCS bus architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRC1*A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e254 × 152 × 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Type\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (Analog\/Digital)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eBuilt-in Surge Suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eDCS Process Control \u0026amp; Connectivity Attributes\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eRC1*A\u003c\/strong\u003e executes high-speed signal processing between field instrumentation and the DCS backplane. To ensure data consistency across distributed networks, the module supports Modbus RTU and Modbus TCP communication protocols, allowing for deterministic data exchange. Channel-to-channel isolation is integrated within the signal path to prevent ground-loop interference and common-mode transients. Furthermore, the module facilitates cold junction compensation (CJC) for integrated temperature inputs, ensuring that terminal temperature fluctuations do not impact the precision of the connected instrumentation. Continuous self-diagnostics monitor the integrity of the input channels, providing proactive fault detection before signal degradation occurs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the RC1*A support hot-swapping within the DCS rack? A: Module replacement must be performed in accordance with the specific system power-down sequence. Always verify the status of the redundant controller and communication bus before disconnecting the module to prevent backplane bus errors.\u003c\/p\u003e\n\u003cp\u003eQ: Are the Modbus RTU and TCP protocols mutually exclusive on this module? A: The module architecture supports concurrent protocol handling; however, confirm the specific channel configuration mapping to ensure that digital data frames are correctly routed to the intended communication registers.\u003c\/p\u003e\n\u003cp\u003eQ: How is the output current limit managed during actuator control? A: The module is rated for a continuous output current of 1 A. Over-current protection circuitry is active; ensure the connected load impedance does not exceed the power supply limits to prevent thermal shutdown of the output channel.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Secure the module into the designated DCS rack slot. Tighten all retaining screws to ensure a low-impedance ground bond between the module chassis and the cabinet earth to maximize the effectiveness of the internal surge protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Utilize shielded twisted-pair instrumentation cable for all analog signal loops. Terminate cable shields at a centralized cabinet-level grounding rail to provide a low-resistance path for electromagnetic noise suppression.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation\u003c\/strong\u003e: Maintain a minimum clearance of 150 mm between signal cabling and high-voltage AC lines to prevent inductive noise coupling into the sensitive signal processing stages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental\u003c\/strong\u003e: Ensure adequate airflow within the rack to maintain the module operating temperature within the specified range of -20 deg C to +70 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43649269497946,"sku":"RC1*A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/521_5b03776f-06f4-4fb8-a5fd-9d5329960ad7.jpg?v=1783912920","url":"https:\/\/www.spareoil.com\/es\/products\/remote-control-i-o-module-yokogawa-rc1-a-centum-vp","provider":"SpareOil Automation","version":"1.0","type":"link"}