{"product_id":"s2bn1d-11130-yokogawa-n-io-base-plate-module-new-original-stock","title":"S2BN1D-11130 Yokogawa N-IO Base Plate Module | New \u0026 Original Stock","description":"\u003ch2\u003eYokogawa S2BN1D-11130 ProSafe-RS N-IO Base Plate\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa S2BN1D-11130\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eS2BN1D\u003c\/strong\u003e Base Plate with Disconnecting Terminal, operates as a dedicated hardware component for field device connection management within ProSafe-RS N-IO platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-1\u003c\/td\u003e\n\u003ctd\u003eWall mount installation profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal block mechanism for field wiring connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eExplosion protection architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eConformal coating matching ISA Standard G3 specifications with a wide operational temperature configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eFixed production design digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS2BN1D-11130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard N-IO base plate chassis orientation footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-55 to +85 deg C (Suffix 3 standard performance range covers -40 to +70 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem link via S2KPB10 power cable; Field Power Supply Rating: 24 V DC (+20% \/ -10%), up to 11.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 channels supporting single or redundant I\/O configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Voltage Protection\u003c\/td\u003e\n\u003ctd\u003eActive detection level less than or equal to 32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Withstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC for 1 minute between I\/O and system; continuous 42 V DC rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Contact Resistance\u003c\/td\u003e\n\u003ctd\u003eInner contact parameters rated at 2 mOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Enclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIEC 60529:2001, IP66 status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Resistance Compliance\u003c\/td\u003e\n\u003ctd\u003eMIL-STD-1344A (Corrosion), MIL-STD-202F (Vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Environment Framework\u003c\/td\u003e\n\u003ctd\u003eSupported on software version R4.01 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Instrumentation Properties\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa S2BN1D-11130 establishes 16 isolated physical channels optimized to run 4-20 mA HART loop protocol passes directly into the N-IO control sub-layer. The hardware traces contain distinct channel-to-channel isolation layouts to block common-mode voltage fluctuations, grounding noise, and dangerous transient overshoots from entering the primary F-SB bus network. When combined with conformal coating matching ISA Standard G3 severity limits, the base plate operates inside aggressive atmospheres while running real-time loop feedback verification and active over-voltage protection cutting off lines spiking above 32 V.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the integrated 32 V over-voltage protection circuit respond when external field power rails spike unpredictably?\u003c\/p\u003e\n\u003cp\u003eA: The onboard hardware monitors the input power feeds continuously. Whenever incoming loops cross the safety threshold and spike above 32 V, the protection circuit cuts the link to safeguard the underlying N-IO modules from over-voltage degradation.\u003c\/p\u003e\n\u003cp\u003eQ: Can the base plate be serviced or have field cables manipulated while the main node continues to execute active safety loops?\u003c\/p\u003e\n\u003cp\u003eA: The base plate uses disconnecting terminal blocks to isolate field wiring loops during maintenance routines. Technicians can open individual terminal segments to check or service a single field channel without shutting down the entire 16-channel row.\u003c\/p\u003e\n\u003cp\u003eQ: What grounding steps must be followed to keep the 1500 V AC dielectric withstanding voltage threshold intact?\u003c\/p\u003e\n\u003cp\u003eA: Connect a heavy copper drain conductor directly to the dedicated M3 screw terminal on the chassis frame. This dedicated pathway routes electromagnetic noise and high-voltage surges straight to the master instrumentation earth, preventing noise from crossing between channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Mechanical Mounting:\u003c\/strong\u003e Secure the assembly firmly inside the control enclosure using the wall mount holes with M4 x 4 screws, or lock it directly onto a standard DIN rail profile. Maintain vertical orientation to allow unrestricted convection cooling across adjacent components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure Clamp Conductor Termination:\u003c\/strong\u003e Insert stripped wire ends directly into the suffix-designated pressure clamp blocks. Ensure the spring mechanism grips the raw copper conductor tightly to prevent high-resistance connection points in high-vibration applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Cable Engagement:\u003c\/strong\u003e Route the main system voltage line through a dedicated S2KPB10 base plate power supply cable assembly. Secure the locking clips completely to keep the 11.0 A continuous power rail stable under heavy load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Signal Cable Segregation:\u003c\/strong\u003e Route all low-voltage analog inputs and F-SB bus cables away from high-voltage AC lines and motor starter circuits. Use dedicated, grounded metal wire tracks inside the cabinet layout to eliminate electromagnetic cross-talk.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43503809724506,"sku":"S2BN1D-11130","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/361._3cd412aa-299a-463b-ade6-ab7bb90b1df8.jpg?v=1781571317","url":"https:\/\/www.spareoil.com\/es\/products\/s2bn1d-11130-yokogawa-n-io-base-plate-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}