{"product_id":"s9343fa-yokogawa-dc-power-cable-assembly-centum-vp","title":"S9343FA Yokogawa DC Power Cable Assembly Centum VP","description":"\u003ch2\u003eYOKOGAWA S9343FA DC Power Cable Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA S9343FA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eS9343FA\u003c\/strong\u003e DC Power Supply Cable Assembly, operates as a dedicated hardware component for internal DC power distribution within Centum VP and ProSafe-RS control platforms. This component executes the physical interconnection between PW48x series power supply modules and FIO\/FCU base plates, maintaining stable electrical delivery across control cabinets.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS9343FA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eFactory defined length for internal routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (DC transmission)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Function\u003c\/td\u003e\n\u003ctd\u003eDC power distribution (PW48x to Base Plate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe S9343FA utilizes shielded conductors to ensure noise immunity within the DCS architecture. In accordance with Yokogawa's internal wiring standards, the assembly maintains channel-to-channel isolation consistency, preventing potential voltage fluctuations from propagating through the power distribution bus. When integrated into FCU or FIO node units, the cable facilitates both single and dual-redundant configurations, ensuring continuous DC supply to mission-critical logic solvers and I\/O base plates under varying industrial load profiles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the S9343FA require specific grounding procedures during installation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. As a shielded power cable, it must be routed to minimize proximity to high-voltage AC lines. Ensure the shield is properly bonded if the installation environment exceeds baseline electromagnetic interference limits.\u003c\/p\u003e\n\u003cp\u003eQ: Is this assembly compatible with non-Yokogawa power supply modules?\u003c\/p\u003e\n\u003cp\u003eA: No. The S9343FA utilizes an exclusive Yokogawa DC connector interface specifically keyed for the PW481, PW482, and PW484 series modules. Mechanical interference will prevent connection to non-specified hardware.\u003c\/p\u003e\n\u003cp\u003eQ: Can the cable be used in systems where the operating temperature exceeds 70 deg C?\u003c\/p\u003e\n\u003cp\u003eA: No. The S9343FA is rated for a maximum operating temperature of 70 deg C. Exceeding this limit compromises the insulation integrity and shielding performance of the cable assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting Path\u003c\/strong\u003e: Install the S9343FA within designated internal wiring ducts. Avoid sharp radii during routing to prevent structural fatigue of the shielded cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Engagement\u003c\/strong\u003e: Insert the exclusive DC connectors into the PW48x power module and the corresponding FIO\/FCU base plate port. Confirm the locking tab is fully seated to ensure vibration resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Validation\u003c\/strong\u003e: For dual-redundant power configurations, install one S9343FA per power supply module. Verify that the power rail mapping at the base plate matches the redundant supply architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinal Inspection\u003c\/strong\u003e: After installation, perform a point-to-point resistance check to verify continuity and ensure no short circuits exist between the DC positive, negative, and ground return paths.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43600562815066,"sku":"S9343FA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/168._c5723fc1-01e4-44b5-a705-0a229302083b.jpg?v=1783303284","url":"https:\/\/www.spareoil.com\/es\/products\/s9343fa-yokogawa-dc-power-cable-assembly-centum-vp","provider":"SpareOil Automation","version":"1.0","type":"link"}