{"product_id":"safety-digital-i-o-module-hima-6080165-himax-himatrix","title":"Safety Digital I\/O Module | HIMA 6080165 HIMax HIMatrix","description":"\u003ch2\u003eHIMA 6080165 HIMax HIMatrix Safety-Related Controller Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA 6080165\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e6080165\u003c\/strong\u003e Safety-Related Controller Module, operates as a dedicated hardware component for safety-critical digital input and output execution within HIMax and HIMatrix network architecture. It manages discrete signal processing and fault-tolerant trip logic while maintaining real-time system diagnostics over high-integrity field connections.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6080165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 x 80 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Redundant input supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHIMax \/ HIMatrix safety controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e16 Digital channels (Configurable as input\/output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eSafeEthernet, RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Coverage\u003c\/td\u003e\n\u003ctd\u003eGreater than 99% fault coverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL3 (IEC 61508, IEC 61511)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail \/ rack mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTriple Modular Redundancy (TMR) Architecture \u0026amp; Fail-Safe Execution\u003c\/h3\u003e\n\u003cp\u003eThe HIMA 6080165 maintains a triple modular redundancy (TMR) 2oo3 architecture integration profile to guarantee fail-safe state execution across active process loops. Integrated galvanic isolation across all 16 digital channels isolates high-voltage electrical surges and prevents cross-talk interference from compromising logic solver operations.\u003c\/p\u003e\n\u003cp\u003eThrough continuous hardware self-testing, the module achieves greater than 99% diagnostic coverage. If an internal component or loop fault occurs, the board automatically forces affected outputs into a defined fail-safe state without dropping backplane network communication. Dual SafeEthernet and RS485 interfaces maintain deterministic signal transmission times under 10 ms across redundant control topologies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the HIMA 6080165 support hot-swap replacement during system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Technicians can replace the module online without interrupting power or data flow to adjacent I\/O modules on the backplane rack.\u003c\/p\u003e\n\u003cp\u003eQ: How does channel-to-channel galvanic isolation protect the logic solver core?\u003c\/p\u003e\n\u003cp\u003eA: Galvanic isolation blocks high-voltage transients, stray ground loops, and field-side short circuits from traveling across terminal connections into the primary 24 VDC system bus.\u003c\/p\u003e\n\u003cp\u003eQ: What action does the module take upon detecting an internal hardware fault?\u003c\/p\u003e\n\u003cp\u003eA: Integrated self-diagnostics identify the fault within milliseconds and immediately drive the affected digital output channels into their predefined, de-energized fail-safe states.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module on a standard DIN rail or rack assembly within an enclosure that meets field environmental requirements. Maintain at least 50 mm of vertical clearance above and below the module chassis to allow unimpeded convection cooling across the -20 to +60 deg C operating temperature range.\u003c\/p\u003e\n\u003cp\u003eRoute 24 VDC power conductors and digital signal wiring in separate wire ducts to prevent electromagnetic interference from coupling onto the I\/O circuits. Connect the main ground wire to a low-impedance safety earth terminal using a short, heavy-gauge conductor strap. Verify all terminal block screw torque parameters before applying power to the primary DC bus.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43782560251994,"sku":"6080165","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/237_8547a89c-22eb-4086-b666-5306829dd614.jpg?v=1785807510","url":"https:\/\/www.spareoil.com\/es\/products\/safety-digital-i-o-module-hima-6080165-himax-himatrix","provider":"SpareOil Automation","version":"1.0","type":"link"}