{"product_id":"schneider-800-series-dap-208-modicon-digital-output-modules","title":"Schneider AS-BDAP-208 Modicon 800 Series Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric AS-BDAP-208 is a specialized relay output module designed for integration within the Modicon 800 Series I\/O architecture. This unit provides 8 independent electromechanical relay channels, facilitating the interface between low-voltage control logic and higher-voltage field load circuits. Engineered for robust performance in demanding industrial environments—including petrochemical processing, thermal power generation, and heavy manufacturing—this module ensures reliable discrete signal switching while maintaining critical galvanic isolation between field devices and the controller backplane.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8-Channel Relay Output:\u003c\/strong\u003e Features eight independent, normally open (NO) mechanical relay contacts for versatile load control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Provides high-capacity dielectric separation between the field wiring and the internal backplane bus, protecting the processor from inductive surges and potential short-circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Protection:\u003c\/strong\u003e Each channel incorporates localized snubber networks to mitigate contact degradation caused by inductive counter-electromotive force during switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Feedback:\u003c\/strong\u003e Front-panel LED indicators provide real-time status monitoring for each individual output channel, allowing for rapid field diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Compatibility:\u003c\/strong\u003e Supports a wide operating voltage range, accommodating both AC and DC load requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAS-BDAP-208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e8 (Normally Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e24 to 240 VAC \/ 24 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating (Per Point)\u003c\/td\u003e\n\u003ctd\u003e2.0 A (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating (Total)\u003c\/td\u003e\n\u003ctd\u003e12.0 A (Cumulative Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (Contact to Backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Power Draw\u003c\/td\u003e\n\u003ctd\u003e320 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e This module contains sensitive electronic components. Always use proper ESD (electrostatic discharge) grounding procedures during installation or maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Safety:\u003c\/strong\u003e Ensure all power to the I\/O rack and field load circuits is disconnected before inserting or removing the module to prevent electrical arcing or damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is fully seated in the designated backplane slot and that the front retaining screws are tightened to provide a secure ground connection to the chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use the provided removable screw terminal block for field connections. Ensure wires are properly stripped and secured to prevent intermittent contact or short circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Install in a clean, dry location within the specified temperature range. Ensure adequate ventilation around the I\/O rack to prevent heat accumulation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the AS-BDAP-208 module?\u003c\/strong\u003e\u003cbr\u003eThe AS-BDAP-208 acts as a relay interface, allowing a Modicon 800 Series controller to safely switch external AC or DC loads by providing galvanic isolation between the control logic and the field devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module handle inductive loads?\u003c\/strong\u003e\u003cbr\u003eYes, the module is equipped with internal snubber networks designed to suppress inductive spikes generated during the switching of coils or other inductive loads.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":44053972189274,"sku":"DAP 208","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_b2a8dedd-4c3a-4fdc-bb68-2c964c377cac.jpg?v=1789198174","url":"https:\/\/www.spareoil.com\/es\/products\/schneider-800-series-dap-208-modicon-digital-output-modules","provider":"SpareOil Automation","version":"1.0","type":"link"}