{"product_id":"schneider-electric-bmxart0814-modicon-x80-analog-input-card","title":"Schneider Electric BMXART0814 Modicon X80 Analog Input Card","description":"\u003ch2\u003eSchneider Electric BMXART0814 Modicon X80 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric BMXART0814\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eBMXART0814\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for multi-channel analog voltage and current signal acquisition within Modicon M340 and M580 PLC platform networks. The hardware scans field-side instrumentation loops and executes successive approximation conversion sequences to update internal data registers via the chassis interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBMXART0814\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.165 kg (0.364 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eModicon X80 standard single-slot module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Voltage Ranges\u003c\/td\u003e\n\u003ctd\u003e0-10 V, +\/-10 V, +\/-5 V, 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Current Ranges\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA, +\/-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e14 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e~1 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e1 MOhm (voltage mode), 250 Ohm (current mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.3% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003e+\/-30 V (voltage mode), +\/-30 mA (current mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Breakdown\u003c\/td\u003e\n\u003ctd\u003eChannel-to-bus and channel-to-ground isolation layers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Diagnostics\u003c\/td\u003e\n\u003ctd\u003eFront panel status LEDs for module health and loop verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing and Backplane Scaling\u003c\/h3\u003e\n\u003cp\u003eThe analog interface module executes real-time data conversion while maintaining structural data alignment with the underlying backplane bus communication velocity constraints. The processed 14-bit digital registers match standard hardware profiles, rendering variables immediately accessible across upper-level Profinet \/ EtherNet\/IP deterministic networks. This design facilitates multi-channel I\/O density scaling routines within the Modicon X80 architecture, maintaining stable sampling intervals and direct firmware flash compatibility across complex processing drops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the internal protection framework respond when a field loop experiences an electrical fault exceeding nominal specifications?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates input clamp circuits providing continuous overvoltage protection up to +\/-30 V in voltage mode and overcurrent containment up to +\/-30 mA in current mode. Field anomalies outside these boundaries trigger the channel-level diagnostic status bits, activate the local red fault LED indicator, and report the hardware exception block over the backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: Is this specific analog input module hot-swappable during runtime execution of the control rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the Modicon X80 mechanical architecture permits removal and insertion under power (RIUP) operations. Field technicians can extract the card or decouple the terminal block assembly without disrupting the host CPU or degrading communications to adjacent hardware racks.\u003c\/p\u003e\n\u003cp\u003eQ: Can single-ended voltage links and active current loops be run together on a single card?\u003c\/p\u003e\n\u003cp\u003eA: Yes, individual channel parameter blocks allow mixed configuration choices across the 8 physical paths. Software variables dictate the internal signal trace layout to select either the 1 MOhm voltage path or the 250 Ohm current shunt resistor loop per channel point.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eSeat the module base into the selected slot on the Modicon X80 backplane chassis, pivoting the assembly until the upper retaining latch engages onto the metal rail. Fasten all lock screws to secure complete grounding path contact through the rear chassis plane. Maintain open air ventilation clearance corridors above and below the module rack to handle thermal dissipation and avoid exceeding the 0 to 60 deg C internal operating limit.\u003c\/p\u003e\n\u003cp\u003eAll sensor links must use shielded, twisted-pair cables sized to match the terminal assembly specifications. Route low-voltage measurement lines through dedicated, enclosed wire trays isolated from high-current AC main circuits or non-shielded variable speed drive lines. Terminate the overall copper shielding braid at a single, low-impedance grounding strip located at the entry panel base plate.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43537040048218,"sku":"BMXART0814","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/227._97c54984-ef88-4090-bb4c-d0a0e18197fa.jpg?v=1782195117","url":"https:\/\/www.spareoil.com\/es\/products\/schneider-electric-bmxart0814-modicon-x80-analog-input-card","provider":"SpareOil Automation","version":"1.0","type":"link"}