{"product_id":"spw482-13-s1-spw482-yokogawa-centum-power-module","title":"SPW482-13 S1 SPW482 Yokogawa CENTUM Power Module","description":"\u003ch2\u003eYokogawa SPW482-13 S1 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 220-240 VAC conversion and regulated DC power delivery in CENTUM VP and ProSafe-RS platforms, the \u003cstrong\u003eYokogawa SPW482-13 S1\u003c\/strong\u003e (\u003cstrong\u003eSPW482\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (SPW482):\u003c\/strong\u003e Yokogawa System Power Supply Module designed specifically for Field Control Units (FCU), FIO Node Units, and Optical ESB Bus Repeater Units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Suffix (-13):\u003c\/strong\u003e Designates the specific nominal 220-240 VAC input voltage rating (operating within 220-240 VAC +\/- 10% at 50\/60 Hz +\/- 3 Hz).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStyle Code (S1):\u003c\/strong\u003e Hardware revision designator denoting the internal component generation, circuit design, and firmware compatibility baseline.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSPW482-13 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 x 20.3 x 14.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 VA maximum input power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e220-240 VAC +\/- 10%, 50\/60 Hz +\/- 3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC regulated (internal system bus distribution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eMaximum 13 A rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant (1+1) configuration, hot-swappable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eExclusive backplane connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003eOvervoltage, overcurrent, short-circuit, overtemperature protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Fieldbus Loop Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe SPW482-13 S1 provides galvanic isolation between the primary 220-240 VAC input mains and the internal system backplane logic rails. This isolation boundary suppresses common-mode voltage spikes and electrical noise, preventing ground loops from disrupting sensitive 4-20 mA HART loop signals, analog field I\/O channels, and optical ESB bus communication interfaces across the node assembly.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the SPW482-13 S1 module be installed in standard generic DIN-rail power configurations?\u003c\/p\u003e\n\u003cp\u003eA: No, the module features an exclusive backplane connector designed solely for mounting within designated power supply slots of Yokogawa FCU, FIO Node Units, and Optical ESB Bus Repeater Units.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping supported when replacing a faulty power module?\u003c\/p\u003e\n\u003cp\u003eA: Yes, live replacement is supported provided the node operates in a dual-redundant (1+1) power configuration and the adjacent secondary module carries the active operational load.\u003c\/p\u003e\n\u003cp\u003eQ: What action should be taken regarding slot location during installation?\u003c\/p\u003e\n\u003cp\u003eA: Install the module directly into dedicated power supply slots P1 or P2 within the rack chassis to ensure alignment with the internal power distribution bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower Source Isolation: Turn off external AC feeder breakers prior to inserting or landing wires on the power assembly, unless conducting a live hot-swap under a verified 1+1 redundant power configuration.\u003c\/li\u003e\n\u003cli\u003eSlot Alignment: Guide the module carefully along the card slot tracks inside the chassis until the rear exclusive multi-pin system connector seats fully into the backplane socket.\u003c\/li\u003e\n\u003cli\u003eRetention Fastening: Tighten the top and bottom panel captive thumbscrews to secure the unit against operational vibration and ensure frame grounding to the chassis enclosure.\u003c\/li\u003e\n\u003cli\u003eCable Segregation: Route incoming high-voltage AC lines in dedicated wire ducts isolated from low-voltage DC signals and optical fiber communication links to avoid electromagnetic interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43859593527386,"sku":"SPW482-13 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/126._2541ec8c-67f4-4bf4-b87d-596a7fe3390b.jpg?v=1787017985","url":"https:\/\/www.spareoil.com\/es\/products\/spw482-13-s1-spw482-yokogawa-centum-power-module","provider":"SpareOil Automation","version":"1.0","type":"link"}