{"product_id":"t9193-ics-triplex-trusted-digital-input-module","title":"T9193 ICS Triplex Trusted Digital Input Module","description":"\u003ch2\u003eICS Triplex T9193 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eICS Triplex T9193\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eT9193\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for high-integrity signal acquisition within Trusted safety system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT9193\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e142 x 92 x 54 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e32 isolated digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eSIL 3 certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHigh-Reliability Safety Control and TMR Architecture\u003c\/h3\u003e\n\u003cp\u003eThe T9193 module utilizes a triple modular redundancy (TMR) 2oo3 architecture to ensure continuous, fault-tolerant digital signal processing. By running three independent input channels in parallel and performing a majority vote on the data, the system masks single-point hardware faults, preventing spurious trips or loss of signal integrity. The module provides galvanic isolation rated at 3000 VAC, which serves as a critical barrier against electrical interference in industrial environments. Advanced onboard diagnostics facilitate fail-safe state execution, with fault detection times maintained at or below 5 ms, ensuring that safety-critical interlocks remain within operational safety parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the T9193 support hot-swapping for module replacement?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the T9193 is designed to support hot-swapping. Its integration within the Trusted TMR architecture allows for the extraction and replacement of a failed module without interrupting the safety system's monitoring of active field inputs.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle signal debounce and Sequence of Events (SOE) logging?\u003c\/p\u003e\n\u003cp\u003eA: The T9193 utilizes high-speed internal logic to provide an SOE resolution of 1 ms. This ensures that rapid state changes from field devices are captured and timestamped accurately, supporting precise post-event diagnostics without the need for additional external hardware.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the module is seated fully into the chassis slot. Align the guide rails with the backplane connectors to prevent pin misalignment during insertion.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the front-panel locking screws to ensure high-vibration stability and proper grounding to the chassis frame.\u003c\/li\u003e\n\u003cli\u003eTerminate all field inputs using shielded cabling to maintain the 3000 VAC isolation barrier. Ensure cable shields are bonded to the designated cabinet earth bar.\u003c\/li\u003e\n\u003cli\u003eVerify that the dual redundant 24 VDC power supplies are correctly terminated at the backplane before applying power to the module.\u003c\/li\u003e\n\u003cli\u003eConfirm that the module front-panel status LEDs indicate normal operation and absence of faults before initiating the system database download.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":43568846241882,"sku":"T9193","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/75._73331dd4-03f2-4daa-afe2-a7bf15ef2f0c.jpg?v=1782702571","url":"https:\/\/www.spareoil.com\/es\/products\/t9193-ics-triplex-trusted-digital-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}