{"product_id":"temperature-control-modules-yokogawa-f3cu04-0s-z01-fa-m3","title":"Temperature Control Modules | Yokogawa F3CU04-0S\/Z01 FA-M3","description":"\u003ch2\u003eYokogawa F3CU04-0S\/Z01 Temperature Control \u0026amp; PID Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3CU04-0S\/Z01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3CU04-0S\u003c\/strong\u003e Temperature Control \u0026amp; PID Module, operates as a dedicated hardware component for closed-loop temperature and process control execution within FA-M3 PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3CU04-0S\/Z01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e200 g (1.10 lbs packaging weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28.9 (W) x 100 (H) x 106.1 (D) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e460 mA at 5 VDC (24 VDC external auxiliary input at 50 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Loops\u003c\/td\u003e\n\u003ctd\u003e4 loops (independent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Size\u003c\/td\u003e\n\u003ctd\u003eSingle-slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eUniversal: Thermocouple (15 types), RTD (9 types), DC voltage (mV\/V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Period\u003c\/td\u003e\n\u003ctd\u003e200 ms (4 loops), 100 ms (2 loops)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler and transformer isolation, withstand 1500 VAC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eTime-proportional PID (open collector, relay\/SSR compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Functions\u003c\/td\u003e\n\u003ctd\u003e12 types (upper\/lower limit, deviation alarms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Outputs\u003c\/td\u003e\n\u003ctd\u003e4 points per loop (with relay linkage for alarms 1 \u0026amp; 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-tuning\u003c\/td\u003e\n\u003ctd\u003eDynamic auto-tuning with fuzzy logic overshoot suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Modes\u003c\/td\u003e\n\u003ctd\u003eCascade control, Heating\/Cooling control supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Cold Junction Compensation\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates transformer and photocoupler isolation across input channels, yielding a dielectric withstand strength of 1500 VAC for 1 minute between signal inputs and internal logic circuitry. Integrated cold junction compensation (CJC) processing operates across all configurable thermocouple ranges, converting microvolt-level thermoelectric potentials into calibrated 0.1 deg C digital values. Sensor input terminals support universal wiring topologies, allowing differential analog sampling for thermocouples, 3-wire RTDs, and low-level DC voltage inputs without external signal conditioning barriers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input sampling speeds are achieved across active control loops? A: The module executes input sampling and PID calculation every 200 ms when operating all 4 loops, or accelerates to 100 ms when restricted to 2 loops.\u003c\/p\u003e\n\u003cp\u003eQ: What cold junction compensation and isolation features protect the temperature inputs?\u003c\/p\u003e\n\u003cp\u003eA: Internal CJC circuitry auto-corrects thermocouple readings while transformer and photocoupler isolation prevents field noise up to 1500 VAC from entering the FA-M3 backplane bus.\u003c\/p\u003e\n\u003cp\u003eQ: How does the dynamic auto-tuning capability handle setpoint variations? A: The module calculates optimal PID parameters automatically upon startup and recalculates constants when operators adjust setpoints or process conditions shift during operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInsert the single-slot module into a designated rack slot on the FA-M3 base unit until the lock mechanism engages. Allow a minimum warm-up period of 30 minutes following power application before conducting calibration or active process execution. Route thermocouple and RTD wiring away from high-voltage motor power leads using grounded shielded cable to minimize electromagnetic interference. Ground cable shields at a single point on the main system signal ground busbar. Verify that any threaded conduit entries achieve a minimum engagement of 5 full NPT threads to satisfy enclosure integrity standards.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43815968112730,"sku":"F3CU04-0S\/Z01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/767.jpg?v=1786324883","url":"https:\/\/www.spareoil.com\/es\/products\/temperature-control-modules-yokogawa-f3cu04-0s-z01-fa-m3","provider":"SpareOil Automation","version":"1.0","type":"link"}