{"product_id":"tsxdey32d2-schneider-electric-32-channel-24vdc-input-module","title":"TSXDEY32D2 Schneider Electric 32-Channel 24VDC Input Module","description":"\u003ch2\u003eSchneider Electric TSXDEY32D2 Modicon Premium Discrete Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric TSXDEY32D2\u003c\/strong\u003e serves as the primary \u003cstrong\u003eTSXDEY32D2\u003c\/strong\u003e Discrete Input Module utilized to execute digital voltage signal acquisition across Modicon Premium Automation platform networks. The module interfaces directly with field sensors and switches, processing incoming 24 VDC positive logic signals into logic states readable by the central processor via the local chassis backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDEY32D2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg (0.66 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Modicon Premium single-slot module format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.0 W baseline + 0.1 W per active channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Number\u003c\/td\u003e\n\u003ctd\u003e32 current sink isolated channels conforming to EN\/IEC 61131-2 Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Power Supply Range\u003c\/td\u003e\n\u003ctd\u003e19-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Input Current\u003c\/td\u003e\n\u003ctd\u003e3.5 mA nominal at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage State 1 Guaranteed\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 11 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage State 0 Guaranteed\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e6300 Ohm at State 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e135 mA at 5 VDC, 160 mA at 24 VDC from backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eHE-10 connector interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 MOhm at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDiscrete Input Density Scaling and Bus Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe hardware module operates within the high-density architecture of the Premium chassis, leveraging specific input density scaling capabilities to monitor 32 concurrent points in a single physical slot allocation. Communication synchronization is governed by the backplane bus communication velocity, transferring bit states to the processor image table within an active scanning window. The hardware architecture contains multi-channel optical isolation paths to separate field-side potentials from internal logic buses, mitigating common-mode noise propagation and ground loop artifacts without reducing signal execution throughput.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the specific electrical state boundaries for a guaranteed transition between logic 0 and logic 1?\u003c\/p\u003e\n\u003cp\u003eA: A logic state 1 is electrically guaranteed when the input voltage reaches or exceeds 11 VDC with a minimum current of 3 mA. Conversely, a logic state 0 is enforced when the voltage drops to or below 5 VDC, or when the loop current drops below 1.5 mA.\u003c\/p\u003e\n\u003cp\u003eQ: How is external field wiring terminated on this specific high-density module?\u003c\/p\u003e\n\u003cp\u003eA: Physical termination is achieved via integrated HE-10 multi-pin ribbon connectors. This configuration requires external pre-wired cable assemblies paired with remote terminal blocks to link the field instrument wire pairs directly to the module interface.\u003c\/p\u003e\n\u003cp\u003eQ: Does this module support online hot-swapping or replacement while the rack is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. The Modicon Premium standard backplane architecture requires that power to the rack configuration be completely isolated before extracting or inserting the module assembly to prevent damage to the logic contacts or bus arbitration faults.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eSecure the standard-format module into the designated slot of the Modicon Premium rack by engaging the bottom tracking clips first, then pivoting the top into place until the locking mechanism latches securely. Tighten the grounding screws to verify continuity between the module frame and the structural panel enclosure ground plate. Ensure ambient conditions inside the cabinet remain within the designated 0 to 60 deg C envelope with unhindered ventilation paths.\u003c\/p\u003e\n\u003cp\u003eField signaling cables attached to the HE-10 interface must be shielded, twisted-pair variants designed for industrial electrical control installations. Route these low-voltage DC input bundles in separate wire trays away from three-phase motor leads, variable frequency drives, and high-energy inductive circuits to avoid electromagnetic noise coupling. Connect the overall cable shields to a centralized, low-impedance ground bar located at the point of enclosure entry.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43536877650010,"sku":"TSXDEY32D2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/222._d42ad85f-e9a7-4f0a-9933-e52122786cd9.jpg?v=1782186980","url":"https:\/\/www.spareoil.com\/es\/products\/tsxdey32d2-schneider-electric-32-channel-24vdc-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}