{"product_id":"versamax-ge-ic200udr040-micro-40-point-plc","title":"VersaMax | GE IC200UDR040 Micro 40-Point PLC","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC200UDR040\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200UDR040\u003c\/strong\u003e Programmable Logic Controller, operates as a dedicated hardware component for discrete process control and field output switching within VersaMax Micro platforms. Powered by a 24 VDC supply voltage, the module processes 24 digital inputs supporting both positive and negative logic configurations alongside 16 normally-open relay outputs. Operating within a 40-point discrete architecture, the device executes real-time logic routines to isolate and actuate field instruments across localized control networks.\u003c\/p\u003e\n\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UDR040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax Micro Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC primary supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Discrete I\/O\u003c\/td\u003e\n\u003ctd\u003e40 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e24 points (Positive\/Negative Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eNormally-Open Relay Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Count\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Backplane Communication \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC200UDR040 executes deterministic scan cycles while managing data transfers to supervisory networks over Profinet or EtherNet\/IP gateways. High I\/O density scaling allows 40 local points to operate simultaneously without degrading internal scan velocity or communication responsiveness. Integrated firmware flash compatibility maintains user program retention and field output state stability during transient DC power sags.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are positive and negative logic configurations selected for the 24 digital inputs?\u003c\/p\u003e\n\u003cp\u003eA: Input logic selection (sink or source) is configured by wiring the field common terminal to either the positive rail or the DC return of the 24 VDC power supply.\u003c\/p\u003e\n\n\u003cp\u003eQ: What are the primary switching characteristics of the output channels on the IC200UDR040?\u003c\/p\u003e\n\u003cp\u003eA: The 16 output channels utilize electromechanical, normally-open relay contacts, providing galvanic isolation for switching independent AC or DC load circuits.\u003c\/p\u003e\n\n\u003cp\u003eQ: Does the IC200UDR040 require a separate power feed for internal logic and relay driving?\u003c\/p\u003e\n\u003cp\u003eA: The controller runs from a primary 24 VDC supply voltage that powers internal processing logic as well as the relay coils.\u003c\/p\u003e\n\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Isolation\u003c\/strong\u003e: De-energize all 24 VDC main power and external output load circuits before mounting, wiring, or inspecting the unit.\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e: Secure the controller onto a standard 35 mm DIN rail or surface-mount it using M4 panel screws. Ensure the mounting rail is bonded to protective earth (PE).\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiscrete Wiring Separation\u003c\/strong\u003e: Route 24 VDC input lines and output load wiring in separate conduit or cable trays away from high-voltage AC power lines to suppress electromagnetic interference.\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Contact Protection\u003c\/strong\u003e: Install inductive surge suppressors (flyback diodes for DC loads or RC snubbers for AC loads) across field-actuated inductive loads to extend relay contact service life.\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management\u003c\/strong\u003e: Maintain at least 50 mm of vertical clearance above and below the controller housing to allow adequate convection airflow across the 0 to 60 deg C operating range.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43791691743322,"sku":"IC200UDR040","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/IC200UDR040.png?v=1785985896","url":"https:\/\/www.spareoil.com\/es\/products\/versamax-ge-ic200udr040-micro-40-point-plc","provider":"SpareOil Automation","version":"1.0","type":"link"}