{"product_id":"vm1-d-yokogawa-centum-vp-hart-enabled-analog-i-o-module","title":"VM1*D YOKOGAWA CENTUM VP HART-Enabled Analog I\/O Module","description":"\u003ch2\u003eYOKOGAWA VM1*D Multipoint Analog I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA VM1*D\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eVM1D\u003c\/strong\u003e Interface Module, operates as a dedicated hardware component for HART-enabled analog signal acquisition and control within CENTUM VP and CS 3000 DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVM1\u003c\/strong\u003e: Base model identifier for multipoint analog I\/O functionality with integrated HART communication capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e*D\u003c\/strong\u003e: Configuration suffix denoting hardware revision and support for dual-redundant deployment within system rack environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVM1*D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e356 × 178 × 51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Type\u003c\/td\u003e\n\u003ctd\u003eAnalog (4-20 mA) \/ HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eFactory\/User-defined storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control \u0026amp; Isolation Attributes\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVM1*D\u003c\/strong\u003e executes high-precision signal processing for field instruments, integrating 16-bit analog-to-digital conversion with digital HART protocol extraction. To ensure measurement integrity, the module employs channel-to-channel isolation to prevent ground-loop interference and common-mode voltage contamination. The integrated HART loop protocol connectivity permits simultaneous analog control and digital diagnostic data logging, facilitating predictive maintenance for connected field devices. Furthermore, the module supports cold junction compensation (CJC) for temperature-based inputs, ensuring that terminal temperature fluctuations do not impact the accuracy of the signal processing chain.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the VM1*D support hot-swapping within the control station? A: Module replacement must be performed according to the specific DCS rack power-down sequence. Always verify current system status and synchronization state before physical removal to prevent backplane bus communication errors.\u003c\/p\u003e\n\u003cp\u003eQ: Is the HART digital data path independent of the 4-20 mA analog signal? A: Yes. The module architecture facilitates the superposition of HART digital signals on the analog current loop, allowing for concurrent data transmission without degrading the primary control signal.\u003c\/p\u003e\n\u003cp\u003eQ: How are calibration values managed during module replacement? A: The module maintains non-volatile storage for both factory calibration constants and user-defined offsets; however, verify the baseline calibration against a calibrated source after installation to ensure system precision.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Seat the module securely into the DCS rack backplane. Tighten all retaining screws to provide a low-impedance ground bond between the module chassis and the cabinet earth.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Utilize shielded twisted-pair instrumentation cable for all analog signal loops. Terminate cable shields at a centralized cabinet-level grounding rail to minimize induced electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation\u003c\/strong\u003e: Maintain a minimum clearance of 150 mm between signal cabling and high-voltage AC lines to prevent inductive noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management\u003c\/strong\u003e: Ensure adequate airflow within the rack environment. While the module is rated for industrial use, prevent air blockages to maintain ambient operational stability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43648969506906,"sku":"VM1*D","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/516_b5fc8763-49cd-4b53-bc5e-54afcbf465c5.jpg?v=1783910693","url":"https:\/\/www.spareoil.com\/es\/products\/vm1-d-yokogawa-centum-vp-hart-enabled-analog-i-o-module","provider":"SpareOil Automation","version":"1.0","type":"link"}