{"product_id":"woodward-micronet-5501-380-plc-power-supply","title":"Woodward 5501-380 MicroNet Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Woodward 5501-380 is a dedicated AC-to-DC power supply module engineered for the MicroNet control system. This unit provides the necessary regulated DC power rails required to maintain stable operation of the MicroNet backplane and connected I\/O modules. Designed for mission-critical industrial applications, including power generation, gas compression, and turbine control, the 5501-380 ensures consistent energy delivery in demanding environments. Its construction focuses on reliability and long-term performance, making it a standard choice for maintaining the integrity of MicroNet control racks.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Efficiency Switching:\u003c\/strong\u003e Utilizes advanced switching topology to reduce power loss and minimize internal cabinet heat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Protection:\u003c\/strong\u003e Includes built-in safety features such as over-voltage, over-current, and short-circuit protection to prevent damage to downstream electronic components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMI Filtering:\u003c\/strong\u003e Features internal circuitry to suppress line transients and electromagnetic interference, providing clean power to logic circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Monitoring:\u003c\/strong\u003e Front-panel indicators allow for immediate visual confirmation of power status and fault diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Design:\u003c\/strong\u003e Engineered for panel mounting within industrial enclosures, supporting operation in temperatures ranging from 0 to 60 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis power supply is specifically designed for integration into Woodward MicroNet control systems. It is commonly deployed in critical infrastructure such as steam turbine management, large-scale power generation facilities, and gas compression stations where high availability and system uptime are mandatory.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5501-380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eMicroNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.39 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Ensure the primary power source is fully disconnected before installing or removing the module from the chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling and Ventilation:\u003c\/strong\u003e Maintain adequate clearance around the module to allow for natural thermal convection. Avoid placing the unit near high-heat sources within the cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Follow standard industrial grounding practices to ensure the chassis is connected to a common earth ground to mitigate EMI risks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Handling:\u003c\/strong\u003e Use proper electrostatic discharge (ESD) prevention measures when handling the module to protect internal circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Keep AC input wiring separate from low-voltage signal cabling to prevent inductive noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 5501-380?\u003c\/h3\u003e\u003cp\u003eThe 5501-380 acts as the primary power supply for the Woodward MicroNet system, converting 120 VAC utility power into the specific DC voltages required by the backplane and associated control modules.\u003c\/p\u003e\u003ch3\u003eIs this module suitable for high-temperature environments?\u003c\/h3\u003e\u003cp\u003eThe module is rated for operation in ambient temperatures between 0 and 60 deg C, making it suitable for most standard industrial control room environments.\u003c\/p\u003e\u003ch3\u003eWhat should I do if the status indicator shows a fault?\u003c\/h3\u003e\u003cp\u003eFirst, verify that the input voltage is within the nominal 120 VAC range and that there are no short circuits on the secondary side. If the fault persists, refer to the MicroNet system maintenance manual for specific diagnostic codes.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":43981977714778,"sku":"5501-380","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_b0be6abc-395e-4db5-bfc8-34f925484ab9.jpg?v=1788232759","url":"https:\/\/www.spareoil.com\/es\/products\/woodward-micronet-5501-380-plc-power-supply","provider":"SpareOil Automation","version":"1.0","type":"link"}