{"product_id":"yokogawa-adv151-p10-s2-centum-vp-digital-input-module","title":"Yokogawa ADV151-P10 S2 Centum VP Digital Input Module","description":"\u003ch2\u003eYokogawa ADV151-P10 S2 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADV151-P10 S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADV151\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for discrete signal acquisition within Yokogawa Centum CS and Centum VP platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-P10 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndonesia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 cm x 12.7 cm x 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA (5 VDC internal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF Voltage\u003c\/td\u003e\n\u003ctd\u003e5.0 VDC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Allowable Input Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Withstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2000 VAC between input signal and system (1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; DCS Loop Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates high-density optoelectronic isolation barriers rated to withstand 2000 VAC between field input lines and the system logic backplane. Designed to operate alongside 4-20 mA HART loop protocol transmitters and analog control buses within the same cabinet, the hardware suppresses common-mode voltage spikes and ground loops across discrete signal paths. Channel circuit logic ensures noise immunity during rapid contact state changes, preventing unwanted transient propagation across backplane communication paths and maintaining deterministic data processing for field limit switches, relays, and emergency trip contact inputs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swap replacement during system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports online insertion and removal (hot-swap) without disrupting system power or interrupting communication on adjacent backplane slots, provided standard field terminal disengagement steps are followed.\u003c\/p\u003e\n\u003cp\u003eQ: What cables and terminal structures connect field devices to this hardware?\u003c\/p\u003e\n\u003cp\u003eA: External connections interface via pressure clamp terminal blocks, MIL connector cables, or the dedicated AKB331 cable assembly depending on system rack configurations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit directly into the designated CENTUM VP or Centum CS I\/O card slot or rack rail until the locking tabs snap into place. Connect field input signal wiring to the pressure clamp terminals or dedicated AKB331 cable connectors according to channel polarity (sink or source configuration). Ground all field cable shielding at a single point at the system earth bar to mitigate ground potential differences. Keep 24 VDC digital input wiring separated from high-voltage AC power lines within the enclosure ducting to prevent electromagnetic coupling.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43859606077530,"sku":"ADV151-P10 S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/177._ab6bc1fc-c1b2-4558-a8f8-f51a8436c91b.jpg?v=1787019836","url":"https:\/\/www.spareoil.com\/es\/products\/yokogawa-adv151-p10-s2-centum-vp-digital-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}