{"product_id":"yokogawa-ks9-10-b-signal-cable-centum-vp-cs-3000-dcs-interface","title":"Yokogawa KS9-10*B Signal Cable CENTUM VP CS 3000 DCS Interface","description":"\u003ch2\u003eYokogawa KS9-10*B Signal Cable\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa KS9-10*B\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eKS9\u003c\/strong\u003e Signal Cable, operates as a dedicated hardware component for high-density discrete signal transmission between I\/O modules and terminal blocks within CENTUM VP and CS 3000 systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eKS9\u003c\/td\u003e\n\u003ctd\u003eBase Model: Signal Cable (50-pin to 50-pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-10\u003c\/td\u003e\n\u003ctd\u003eLength: 10 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e*B\u003c\/td\u003e\n\u003ctd\u003eStyle B: Revision B Connector Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKS9-10*B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10 meter length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eN\/A (Passive component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eShielded twisted-pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e50-pin high-density plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe KS9-10*B utilizes multi-core shielded construction to maintain channel-to-channel isolation performance across the distributed control network. The physical design integrates full EMI\/RFI shielding to suppress crosstalk during high-speed signal propagation. When utilized with 4-20 mA HART loop protocol instruments, the cable maintains impedance consistency, preventing signal attenuation over the 10 meter span. Effective integration requires strict adherence to pin-out mapping to ensure that the discrete logic levels remain within the DCS input specification range.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the KS9-10\u003ci\u003eB be field-terminated if the cable length needs to be shortened? A: No. The KS9\u003c\/i\u003eB series cables are factory-terminated and tested to meet specific impedance and shielding standards. Modifying the cable length or connector interface invalidates the EMI protection ratings and may lead to signal reflection or packet loss in the DCS bus.\u003c\/p\u003e\n\u003cp\u003eQ: What are the constraints regarding cable bending during installation?\u003c\/p\u003e\n\u003cp\u003eA: Maintain a minimum bending radius of at least 10 times the cable diameter to prevent mechanical stress on the internal tinned copper conductors and to maintain the integrity of the shielding layer.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting:\u003c\/strong\u003e Avoid routing signal cables in parallel with high-voltage power lines or variable frequency drive (VFD) output cables. Maintain a minimum separation distance of 300 mm to prevent inductive interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e Secure the cable at regular intervals using cable trays or ties. Do not allow the weight of the cable to pull directly on the 50-pin connectors; ensure the connectors are fully seated and latched to the I\/O module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e While the cable includes an internal shield, ensure the cabinet ground system is robust. The connector shell should make solid contact with the module housing to establish a continuous ground path for shield termination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspection:\u003c\/strong\u003e Periodically inspect the PVC jacket for physical damage or degradation caused by ambient chemical exposure. Replace the cable if the outer jacket is breached, as moisture ingress will degrade the insulation resistance of the internal twisted pairs.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43655319847002,"sku":"KS9*B","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/533_ca0c5e9c-51a1-4cd0-8d48-a8bc63fbd926.jpg?v=1783996406","url":"https:\/\/www.spareoil.com\/es\/products\/yokogawa-ks9-10-b-signal-cable-centum-vp-cs-3000-dcs-interface","provider":"SpareOil Automation","version":"1.0","type":"link"}