{"product_id":"00014647-00-bachmann-bms-hvac-integration-module","title":"00014647-00 Bachmann BMS HVAC Integration Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBachmann 00014647-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance communication gateway, bridging Bachmann programmable logic controllers (PLCs) with BACnet MS\/TP networks. This module eliminates the need for expensive external protocol converters by providing native BACnet integration. It excels in Building Management Systems (BMS) and smart infrastructure, allowing the PLC to manage up to 128 BACnet objects simultaneously. We supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition with original packaging, ensuring a seamless, high-reliability link between your industrial hardware and facility management layers.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 00014647-00 utilizes a high-speed processing core to handle complex object management and real-time alarm synchronization.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBachmann electronic GmbH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e00014647-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBACnet MS\/TP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eObject Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 128 BACnet Objects\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Discovery, Property Access, Alarm\/Event Handling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTime Synchronization Support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug-and-Play System Integration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in Network Health Monitoring Tools\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAustria\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 00014647-00 optimizes building automation projects by simplifying the data hierarchy and reducing commissioning time.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNative Protocol Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy embedding BACnet MS\/TP capabilities directly into the PLC rack, this module removes the latency and points of failure associated with third-party gateways. This direct link ensures faster response times for critical HVAC and lighting control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutomated Device Discovery:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes an \"auto-discovery\" algorithm to identify existing BACnet devices on the network. This feature significantly reduces manual configuration errors and slashes commissioning hours during large-scale infrastructure deployments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable Object Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupporting up to 128 objects—including analog inputs, binary outputs, and multistate variables—the 00014647-00 handles the density required for complex chillers, air handling units (AHUs), and energy monitoring systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Diagnostic Suite:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated software tools monitor network health and traffic load. Engineers use these diagnostics to troubleshoot baud rate mismatches or address conflicts without requiring external protocol analyzers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile primarily used in commercial BMS, the module meets CE industrial standards. Its rugged construction resists electromagnetic interference (EMI) and temperature fluctuations typical of mechanical plant rooms and industrial rooftops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support BACnet\/IP or just MS\/TP?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 00014647-00 specifically supports the BACnet MS\/TP (Master-Slave\/Token-Passing) protocol over twisted-pair wiring. For BACnet\/IP requirements, please consult our alternative Bachmann networking modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the 128 objects?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfiguration occurs through Bachmann’s standard engineering environment. The \"plug-and-play\" architecture allows you to map PLC internal variables directly to BACnet object properties with minimal coding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module act as a BACnet Time Master?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module supports time synchronization functions, allowing it to either receive time updates from a central BMS or broadcast its internal clock to synchronize other devices on the MS\/TP segment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 00014647-00 compatible with older Bachmann PLC series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module integrates with the current M1 automation system. Always verify your specific CPU firmware version to ensure full support for the latest BACnet object profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":43166106452058,"sku":"00014647-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/472.jpg?v=1775035342","url":"https:\/\/www.spareoil.com\/products\/00014647-00-bachmann-bms-hvac-integration-module","provider":"SpareOil Automation","version":"1.0","type":"link"}