{"product_id":"140aco13000-140aco13000-modicon-quantum-analog-output-module","title":"140ACO13000 140ACO13000 Modicon Quantum Analog Output Module","description":"\u003ch2\u003eSchneider Electric 140ACO13000 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-precision loop control in Modicon Quantum PLC platforms, the \u003cstrong\u003eSchneider Electric 140ACO13000\u003c\/strong\u003e (\u003cstrong\u003e140ACO13000\u003c\/strong\u003e Analog Output Module) provides direct electrical execution of 4-20 mA or 0-20 mA current signals to drive actuators, valves, and variable-speed drives.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140ACO13000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Quantum Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e300 mA (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ranges\u003c\/td\u003e\n\u003ctd\u003e4-20 mA \/ 0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit (0-4095 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1780 Vrms (Field to Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Diagnostic Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe 140ACO13000 integrates per-channel broken wire detection, which provides real-time monitoring of output loop integrity. Diagnostic status is mapped to the controller via 4 input words, enabling proactive fault detection and minimizing process deviation during cable interruptions. The module supports a load impedance range of 0 to 600 Ohm at 24 VDC field supply, ensuring compatibility with most industrial actuators. The design incorporates galvanic isolation between the system bus and field circuits, maintaining high-availability signal output even in harsh electromagnetic environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are the internal fuses accessible for replacement if a loop short circuit occurs?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 140ACO13000 features accessible internal fusing per group, located behind the front protective door of the module. This allows for rapid recovery from field-side short circuits without requiring the removal of the entire module from the backplane.\u003c\/p\u003e\n\u003cp\u003eQ: How is the broken wire detection function monitored by the PLC?\u003c\/p\u003e\n\u003cp\u003eA: The diagnostic feedback for broken wire detection is transmitted to the PLC CPU through 4 designated input words. When a loop is interrupted, the module sets the corresponding bit in the diagnostic registers, allowing the logic program to initiate an alarm or trigger a fail-safe state for the associated process control loop.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Seat the module firmly into the Quantum I\/O rack. Ensure the front door assembly is properly closed after wiring to maintain the module's environmental integrity and access to the fuse blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power:\u003c\/strong\u003e An external 24 VDC nominal power supply is mandatory for the operation of the output loops. Ensure this supply is adequately filtered and grounded according to instrumentation standards to prevent ripple-induced output noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Utilize shielded twisted-pair cables for all current outputs to prevent EMI-induced fluctuations. Terminate the shield at the cabinet ground bus, ensuring that the shield path remains consistent and is not utilized as a current return path.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":42870873227354,"sku":"140ACO13000","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/87_a143c24b-b6f4-43a5-8e15-1ec9eb982fba.jpg?v=1772156228","url":"https:\/\/www.spareoil.com\/products\/140aco13000-140aco13000-modicon-quantum-analog-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}