{"product_id":"140ddo84300-schneider-electric-modicon-quantum-datasheet","title":"140DDO84300 Schneider Electric Modicon Quantum Datasheet","description":"\u003ch2\u003eSchneider Electric 140DDO84300 Modicon Quantum Series\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider Electric 140DDO84300\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e140DDO84300\u003c\/strong\u003e Discrete Output Module, operates as a dedicated hardware component for solid-state DC switching tasks within Modicon Quantum automation platforms. The module manages 16 independent channels organized into isolated groups to execute positive source logic commands, transferring discrete control profiles directly from the processor backplane to field-side actuators without auxiliary relay components.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140DDO84300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (0.99 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e398 mm x 41 mm x 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1 W + (1 V x total module load current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 Channels (2 groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Outputs (Positive source logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Output Voltage\u003c\/td\u003e\n\u003ctd\u003e10 to 60 VDC (Limits: 10.2 to 72 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Output\u003c\/td\u003e\n\u003ctd\u003e72 VDC permanent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e12 A per module (6 A per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Bus Current\u003c\/td\u003e\n\u003ctd\u003e160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms (State 0 to 1 and State 1 to 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation between Channels and Bus\u003c\/td\u003e\n\u003ctd\u003e2500 Vrms DC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% Without Condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks Integration\u003c\/h3\u003e\n\u003cp\u003eThe 140DDO84300 module interfaces with remote communication drops to align discrete switching cycles with Profinet \/ EtherNet\/IP deterministic networks. By requiring exactly 1 output word for I\/O density scaling, the internal hardware execution guarantees end-to-end signal propagation response times of \u0026lt;= 1 ms. This fixed mapping profile allows the host controller to maintain synchronous network update loops across long-distance topologies while mitigating data latency or channel-to-channel communication skew under peak inductive load demands.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the internal protection limitations if an external field wire experiences a short circuit?\u003c\/p\u003e\n\u003cp\u003eA: Each group of 8 channels contains an internal 8 A fuse designed to isolate catastrophic over-current faults. Individual output points are rated for a 2 A maximum fuse threshold, and exceeding the 6 A group limit or 12 A total module limit will trigger thermal protection or open the group fuse.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be configured to drive negative logic or sinking field circuits?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal transistor architecture of the 140DDO84300 is hardwired strictly for positive logic (source) operations, where the module supplies voltage directly to the load from the external DC power supply rail.\u003c\/p\u003e\n\u003cp\u003eQ: What is the absolute voltage limit before the solid-state components suffer insulation breakdown?\u003c\/p\u003e\n\u003cp\u003eA: The module is rated for a permanent maximum of 72 VDC. Isolation barriers between the independent channel groups and the low-voltage logic bus are rated up to 2500 Vrms DC for a duration of 1 minute.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Insertion:\u003c\/strong\u003e Fit the module into any available slot of the Modicon Quantum rack assembly. Press firmly until the local signaling LEDs line up with the adjacent modules and secure the screw retainers to verify ground continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Environment:\u003c\/strong\u003e Install the rack inside an IP20-rated enclosure protected from airborne particulates and corrosive chemicals. Maintain adequate convection pathways to ensure the ambient internal air does not exceed 60 deg C under maximum load current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Inductive Loads:\u003c\/strong\u003e Group active field wiring away from low-voltage network cables. For highly inductive loads, confirm that the system adheres to the specified limit configuration formula, $\\text{Inductance(H)} = 0.5 \/ ((\\text{current(A)})^2 \\times (\\text{switching frequency(Hz)}))$, to suppress back-EMF spikes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43441583292506,"sku":"140DD084300","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/158.1_9603fcc2-6570-4b49-bfae-ea3a2b91e163.jpg?v=1780372832","url":"https:\/\/www.spareoil.com\/products\/140ddo84300-schneider-electric-modicon-quantum-datasheet","provider":"SpareOil Automation","version":"1.0","type":"link"}