{"product_id":"140sai94000s-schneider-modicon-quantum-datasheet-technical-manual","title":"140SAI94000S Schneider Modicon Quantum Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eSchneider 140SAI94000S Modicon Quantum Safety Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSchneider 140SAI94000S\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e140SAI94000S\u003c\/strong\u003e Analog Safety Input Module, operates as a dedicated hardware component for precise analog signal acquisition within Modicon Quantum safety instrumented systems. The module interfaces with external field transmitters to process up to 8 continuous current loops over a high-resolution conversion matrix. Electrical parameters are digitized and transmitted directly to the safety controller backplane, executing continuous diagnostic checks to ensure operational integrity under defined threshold configurations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e140SAI94000S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric (Modicon)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg (1.10 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e47 mm x 162 mm x 315 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e0-25 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Max Input\u003c\/td\u003e\n\u003ctd\u003e35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Error\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2 uA (0 to 60 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e287 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e65 dB at 60 Hz, 70 dB at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e15 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Channel-Bus)\u003c\/td\u003e\n\u003ctd\u003e1500 V AC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Channel-Channel)\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Current Requirement\u003c\/td\u003e\n\u003ctd\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, HazLoc, TUV Rheinland SIL2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe Schneider 140SAI94000S utilizes dedicated internal safety logic that syncs with standard backplane bus communication velocity licenses. The 16-bit analog-to-digital converters process inputs within a fixed 15 ms update window, mapping the data directly into the processor memory map.\u003c\/p\u003e\n\u003cp\u003eWhen integrated into Profinet \/ EtherNet\/IP deterministic networks via safety drop adapters, the module maintains strict timing loops required for industrial process verification. The hardware supports exact I\/O density scaling profiles, enabling simultaneous deployment of multiple safety modules across the same rack without introducing data jitter or degradation of the TUV Rheinland SIL2 performance characteristics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 140SAI94000S module be hot-swapped while the safety rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. Live insertion or removal of this safety module can induce transient electrical noise on the backplane parallel bus. This disrupts execution of the safety runtime environment and may trigger an uncommanded trip or force the safety rack into an offline fault state.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle a field wire break or an input signal exceeding 25 mA?\u003c\/p\u003e\n\u003cp\u003eA: The module executes continuous internal diagnostics. If an input exceeds the 25 mA boundary or drops below structural parameters indicative of an open circuit, the dedicated local channel fault LED illuminates and a diagnostic fault attribute is transferred to the controller to initiate safety state actions.\u003c\/p\u003e\n\u003cp\u003eQ: Is this safety module backward compatible with standard non-safety Modicon Quantum processors?\u003c\/p\u003e\n\u003cp\u003eA: No. The 140SAI94000S requires specific Quantum safety CPUs and executive firmware configurations that support safety-validated I\/O addressing and functional diagnostics.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure all primary instrumentation loop power and chassis backplane power supplies are fully de-energized before mounting the module.\u003c\/li\u003e\n\u003cli\u003eInstall the hardware strictly within a protected IP20 or higher industrial enclosure to shield the internal circuitry from conductive dust and atmospheric moisture.\u003c\/li\u003e\n\u003cli\u003eConnect the individual channel signal cable shields directly to a dedicated low-impedance instrument ground bar within the enclosure, ensuring the shield remains ungrounded at the field transmitter end.\u003c\/li\u003e\n\u003cli\u003eMaintain a structural separation distance of at least 30 cm between the 0-25 mA low-voltage input loops and high-voltage AC power distribution runs or motor control cables.\u003c\/li\u003e\n\u003cli\u003eVerify all terminal block screw connections are torqued to manufacturer specifications to eliminate loose physical contacts that can induce measuring linearity errors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":43446583820378,"sku":"140SAI94000S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/169_bdd5eca6-264d-4b65-95a3-585f920939be.jpg?v=1780457192","url":"https:\/\/www.spareoil.com\/products\/140sai94000s-schneider-modicon-quantum-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}