{"product_id":"1440-rma00-04rc-allen-bradley-xm-series-datasheet-technical-manual","title":"1440-RMA00-04RC Allen-Bradley XM Series Datasheet \u0026 Technical Manual","description":"\u003ch2\u003eAllen-Bradley 1440-RMA00-04RC XM Monitoring Modules\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1440-RMA00-04RC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1440-RMA00-04RC\u003c\/strong\u003e Measurement Module, operates as a dedicated hardware component for industrial machinery monitoring within XM Monitoring Modules networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1440-RMA00-04RC (XM-440)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg (0.51 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e9.3 cm x 7.6 cm x 4.8 cm (3.8 in x 3.7 in x 3.7 in with base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 120 mA, 3.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e4 relays (expandable to 12 via XM-441 expansion modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Operation\u003c\/td\u003e\n\u003ctd\u003eRemote, shared, and voted relay operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators\u003c\/td\u003e\n\u003ctd\u003eModule (red\/green), Network (red\/green), Relay 1-4 (red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviceNet Baud Rates\u003c\/td\u003e\n\u003ctd\u003e125, 250, or 500 Kbps (auto-set by bus master)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232 via mini-connector or terminal base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Baud Rate\u003c\/td\u003e\n\u003ctd\u003eFixed at 19.2 Kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eLocal configuration via XM Serial Configuration Utility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eTerminal Base (DIN-rail or panel mount)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Integration\u003c\/h3\u003e\n\u003cp\u003eThe 1440-RMA00-04RC implements dedicated logic processing matching the backplane bus communication velocity metrics required for deterministic network coordination. Designed to integrate directly with internal DeviceNet infrastructures, the module supports specific I\/O density scaling routines by functioning as a bus master for auxiliary distributed XM measurement devices. To prevent data transmission mismatch, the controller demands strict firmware flash compatibility across all interconnected processing components to manage explicit parameters and voted logic states.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1440-RMA00-04RC draw its primary operating power from the DeviceNet network cable?\u003c\/p\u003e\n\u003cp\u003eA: No. The hardware utilizes independent module power via a dedicated 24 VDC connection on the terminal base unit. The DeviceNet network link is electrically isolated and used strictly for data transmission, not for driving internal circuit logic or relay coils.\u003c\/p\u003e\n\u003cp\u003eQ: How is the DeviceNet baud rate configured on the module?\u003c\/p\u003e\n\u003cp\u003eA: The module does not use hardware switches for network speed configuration. The DeviceNet baud rate is auto-set by the designated bus master or established via the RS-232 serial connection using the local XM Serial Configuration Utility during initial commissioning.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Base Insertion\u003c\/strong\u003e: Mount the module firmly into its corresponding terminal base unit. Ensure the mechanical alignment keys fit properly before locking the assembly onto the DIN-rail or mounting panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Output and Power Wiring\u003c\/strong\u003e: Terminate all 24 VDC power connections and relay contact outputs to the specified terminals on the base. Route signal lines away from high-voltage AC cables to limit noise injection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Practice\u003c\/strong\u003e: Connect the cable shields to a dedicated, low-impedance functional earth grounding point on the terminal base block. Proper termination is necessary to eliminate transient interference on the RS-232 and DeviceNet communication lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43420757491802,"sku":"1440-RMA00-04RC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/174_2c5016a4-d180-49fb-9cd9-f80a52771506.jpg?v=1779844907","url":"https:\/\/www.spareoil.com\/products\/1440-rma00-04rc-allen-bradley-xm-series-datasheet-technical-manual","provider":"SpareOil Automation","version":"1.0","type":"link"}