{"product_id":"1492-taifm16-f-3-ab-16-channel-fused-analog-terminal-block","title":"1492-TAIFM16-F-3 AB 16-Channel Fused Analog Terminal Block","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1492-TAIFM16-F-3 (Series C) operates as a highly specialized, 16-channel Fused Interface Module (IFM) designed to bridge field wiring with ControlLogix programmable automation controllers. This industrial terminal block module integrates directly into functional safety architectures, providing explicit hardware compatibility with dual 1756-IF16 analog input modules deployed in Safety Integrity Level 2 (SIL2) safety shutdown systems. The module routes 16 independent analog current or voltage signals from remote process sensors while enforcing electrical isolation and overcurrent protection via built-in fuse sockets. A dedicated on-board Master relay manages critical shutdown sequences during emergency trip demands. We supply this component strictly as a 100% brand new, original factory-sealed unit to guarantee intact internal safety relays and absolute electrical terminal conductivity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe table below specifies the exact electrical limitations, terminal capacities, and mechanical parameters for the 1492-TAIFM16-F-3 hardware interface:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1492-TAIFM16-F-3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1492 Interface Module (IFM) Family\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLifecycle Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original Factory Stock\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMeets SIL2 Standards for Safety Shutdown Operations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Field Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels (Analog Input Interface)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget PLC Card Match\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual 1756-IF16 Analog Input Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Operating Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Volts DC (For Power and I\/O Signals)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Voltage Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 Volts AC \/ DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Current Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Amperes per individual point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOnboard Interlock Component\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Master Safety Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eField Wiring Connector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFixed Rugged Screw Clamp Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePLC System Interface Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eD-Shell Multi-Pin Cable Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAcceptable Wire Sizes\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 to 12 AWG Conductors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Mount Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated 35 mm DIN-Rail Snap Clip\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 x 80 x 40 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg (0.55 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Protection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen-Style Construction (Requires Cabinet Mount)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTurnkey SIL2 Safety Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis interface module coordinates directly with standard 1756-IF16 analog inputs to form verified SIL2 safety voting loops. The on-board Master relay acts as a hardwired safety interlock, ensuring predictable shutdown execution during critical manufacturing failures or chemical processing overpressure states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid D-Shell Multi-Pin Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe back-end wiring harness layout replaces discrete point-to-point PLC terminal block wiring with a single, secure D-Shell pre-wired cable connector assembly. This engineered interface cuts control cabinet installation timelines by up to eighty percent and eliminates human wire-mapping errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLocalized Channel Overcurrent Fusing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual channel fuse blocks intercept high-energy electrical faults right at the field entry point. If a field instrument shorts out, the corresponding fuse clears the circuit locally, preserving the operational state of adjacent channels and preventing high-voltage overloads from frying the expensive 1756 ControlLogix I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy-Duty Screw Clamp Contacts:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe field-side termination block utilizes fixed, vibration-resistant screw clamp plates that handle large conductor gauges from 22 down to 12 AWG. This high-torque clamping pressure resists the wire loosening commonly caused by ambient industrial floor vibrations near hydraulic pumps and stamping presses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Space Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact 120 x 80 x 40 mm physical layout packs 16 fused analog channels, loop power distribution paths, and an active safety master relay onto a single DIN-rail base. This consolidation frees up massive amounts of horizontal panel space inside crowded low-voltage Marshalling cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1492-TAIFM16-F-3 to drive high-power AC industrial motors directly from its terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This module handles low-voltage control and analog signals up to a nominal 24V DC for safety sensing loops, though its absolute isolation threshold reaches 300V. You must route the module outputs through independent, high-capacity motor starters, contactors, or auxiliary power relays to switch high-current or high-voltage mechanical loads safely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of cable must I order to link this module to my ControlLogix 1756 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1492-TAIFM16-F-3 requires matching pre-wired D-Shell cable assemblies from Rockwell Automation's 1492 wiring system catalog. These cables feature the specific D-Shell socket on one end to snap onto this module and the matching 1756 Removable Terminal Block (RTB) housing on the other end to fit your 1756-IF16 cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhy must I install this specific Series C module inside an environmental control enclosure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1492-TAIFM16-F-3 carries an open-style industrial enclosure rating, exposing its internal busbars, fuses, and relay housings to ambient air. To prevent moisture condensation, conductive airborne dust, and accidental tool contact from shorting the safety circuits, you must install the unit inside a protected NEMA Type 4 or IP54-rated industrial control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43387980415066,"sku":"1492-TAIFM16-F-3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/62_006f2c11-39a3-421e-82e9-239f70d885b7.jpg?v=1779072948","url":"https:\/\/www.spareoil.com\/products\/1492-taifm16-f-3-ab-16-channel-fused-analog-terminal-block","provider":"SpareOil Automation","version":"1.0","type":"link"}