{"product_id":"16-ch-field-termination-assembly-new-honeywell-fc-tsgash-1624","title":"16-Ch Field Termination Assembly | New Honeywell FC-TSGASH-1624","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-TSGASH-1624\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-integrity, 16-channel Safe Digital Output field termination assembly for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Manager SC (S300 IOTA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystem. This module bridges the Safety Manager controller and field actuators, converting logic demands into precise 24 VDC control signals. It drives critical devices such as solenoids, interposing relays, and emergency shutdown valves in hazardous environments. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your safety-instrumented system (SIS) maintains its SIL3 rating and operational integrity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-TSGASH-1624 \/ FC-TSGASH-1624P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Independent Digital Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 2 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Certification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL3 (IEC 61508 Compliant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel and channel-to-bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in line monitoring and fault detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHot-swap Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22.5 cm x 10.8 cm x 8.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.52 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Actuation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-channel design maximizes I\/O density within the S300 IOTA rack. This allows engineers to manage extensive valve arrays and safety interlocks from a single module, effectively reducing cabinet footprint and total installation costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL3 Safety Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEvery channel undergoes rigorous diagnostic testing to meet IEC 61508 SIL3 requirements. The module ensures that critical safety actions—such as isolating a fuel line—execute without fail, even in complex process scenarios.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eActive Line Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated diagnostics perform continuous checks for open circuits and shorted wiring. The module detects field-side faults immediately, providing real-time feedback to the controller to prevent \"fail-to-danger\" conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust isolation barriers protect the internal system backplane from field-side transients and electromagnetic interference (EMI). This prevents a localized electrical fault at a field actuator from cascading through the safety rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environmental Endurance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for the toughest industrial sites, the module operates across a broad thermal spectrum from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–40°C to +85°C\u003c\/strong\u003e. This capability permits installation in unheated remote instrument enclosures (RIE) in harsh geographic regions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull hot-swap support allows technicians to replace the module under power. This feature eliminates the need for process shutdowns during routine hardware maintenance, ensuring 24\/7 system availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the FC-TSGASH-1624 drive high-current solenoids?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Each of the 16 channels supports up to 2 A of switching current. This high capacity allows the module to drive most industrial 24 VDC solenoids and actuators directly without needing additional interposing relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific IOTA base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FC-TSGASH-1624 integrates specifically with the S300 IOTA (Input Output Termination Assembly) architecture within the Honeywell Safety Manager SC system. Always verify the mechanical compatibility of your mounting base before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"P\" suffix found on some versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"P\" typically indicates specific packaging or revision levels designed for global distribution (e.g., via DHL\/FedEx). Mechanically and electrically, the FC-TSGASH-1624 and FC-TSGASH-1624P function identically within the safety loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle short circuits in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features built-in overcurrent protection and diagnostics. If it detects a short circuit, it isolates the affected channel and reports a fault to the Safety Manager, protecting the rest of the module from damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43187944226906,"sku":"FC-TSGASH-1624","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/412._d52621a3-2032-4e1b-b427-ed1953ee04fe.jpg?v=1775552359","url":"https:\/\/www.spareoil.com\/products\/16-ch-field-termination-assembly-new-honeywell-fc-tsgash-1624","provider":"SpareOil Automation","version":"1.0","type":"link"}