{"product_id":"16-channel-voltage-input-prosafe-rs-sdv144-s13-yokogawa","title":"16-Channel Voltage Input | ProSafe-RS | SDV144-S13 Yokogawa","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa SDV144-S13\/B4D00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density analog voltage acquisition interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol platforms. This module captures 16 channels of isolated voltage signals from field instruments, providing a high-fidelity data bridge between field sensors and the central control processor. Engineered for the Field I\/O (FIO) family, the SDV144-S13 excels in demanding oil \u0026amp; gas, chemical, and power generation environments where rapid signal processing (10ms update) and robust channel-to-channel isolation are mandatory for operational safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New Original.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: SDV144 Series\u003c\/h3\u003e\n\u003cp\u003eYokogawa utilizes specific alphanumeric coding to define the hardware revision and interface specifications of the SDV144 series.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSDV144\u003c\/strong\u003e: Isolated Analog Voltage Input Module (16-Channel).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-S\u003c\/strong\u003e: Standard type for FIO systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Style code (indicates specific hardware generation and component baseline).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3\u003c\/strong\u003e: Enhanced durability revision for broader industrial compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB4D00\u003c\/strong\u003e: Equipped with a dual-redundant pressure clamp terminal block for direct wiring (without surge absorber).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe SDV144-S13\/B4D00 combines 12-bit precision with extreme isolation to protect sensitive control logic.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Individually Isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 V to +10 V, 1 to 5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12-bit conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1% of Full Scale (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Update Period\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel and Channel-to-system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-Redundant Pressure Clamp (\/B4D00)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +50°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 × 107.5 × 32.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Control Loop Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 10ms update period enables the Distributed Control System (DCS) to track process variables in near real-time. This speed proves vital for surge control, pressure regulation, and high-speed safety interlocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGround Loop Elimination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFull channel-to-channel isolation suppresses electrical noise and prevents ground potential differences from contaminating signal integrity. This architecture ensures that a single field device fault does not disrupt the remaining 15 signal loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Redundant Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \/B4D00 option integrates dual-redundant pressure clamp terminals directly into the module footprint. This design saves significant cabinet space compared to external marshaling panels and provides a vibration-proof connection that resists the mechanical stress of industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Module Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module executes continuous internal self-checks. It monitors input signal health and internal hardware status, reporting faults to the Human Interface Station (HIS) immediately to facilitate proactive maintenance and prevent unplanned shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the SDV144-S13\/B4D00 handle 4-20 mA current signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Although natively a voltage input module (1-5V), you can monitor standard 4-20 mA current loops by installing a precision 250-ohm shunt resistor across the terminal inputs to convert the current into a compatible voltage signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary benefit of the \/B4D00 terminal block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \/B4D00 option provides a dual-redundant pressure clamp interface. This allows you to wire field devices in a redundant configuration directly to the module, ensuring continuous data acquisition even during a single-path wiring failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the SDV144-S13 compatible with legacy CS 3000 systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. As part of the Yokogawa FIO family, the SDV144-S13 maintains backward compatibility with CENTUM CS 3000 systems while being fully optimized for the latest CENTUM VP and ProSafe-RS hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require an external power supply for the field sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The SDV144-S13 focuses on signal acquisition. While it processes the incoming voltage, your field transmitters typically require a separate 24V DC loop power supply, unless they are self-powered voltage sources.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43155463798874,"sku":"SDV144-S13\/B4D00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/171._5465b87a-fdb8-4832-81f0-8b83dd3bcc0a.jpg?v=1774926824","url":"https:\/\/www.spareoil.com\/products\/16-channel-voltage-input-prosafe-rs-sdv144-s13-yokogawa","provider":"SpareOil Automation","version":"1.0","type":"link"}