{"product_id":"1600071-001-triconex-cbyy33001-2-terminal-board-module","title":"1600071-001 Triconex CBYY33001-2 Terminal Board Module","description":"\u003ch2\u003eTriconex 1600071-001 Terminal Board Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eTriconex 1600071-001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1600071-001\u003c\/strong\u003e Terminal Board Module, operates as a dedicated hardware component for field signal interface execution within Triconex safety instrumented system networks. Configured to interface with 16 digital output points or up to 8 independent supervised frequency input channels, the hardware routes electrical inputs ranging from 0-24 VDC up to 20 kHz speed pulses directly into the triple redundant architecture. The component maintains a system response latency of less than 10 ms while continuously monitoring lines for structural field loop degradation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1600071-001 (CBYY33001-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTriconex (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.20 lbs (2.0 kg configuration base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.5 x 4.5 x 5.5 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/-10%, less than or equal to 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003e0-24 VDC Digital \/ Frequency Pulse (0-20 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of I\/O Points\u003c\/td\u003e\n\u003ctd\u003e16 Digital Outputs \/ 8 Supervised Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003eGreater than or equal to 1500 VDC channel-to-channel and field-to-backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Matrix\u003c\/td\u003e\n\u003ctd\u003eTriple Modular Redundancy (TMR) 2oo3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eIEC 61508 SIL 3 Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTriple Modular Redundancy (TMR) 2oo3 Architecture\u003c\/h3\u003e\n\u003cp\u003eThe hardware utilizes isolated signal paths designed to pair with a triple modular redundancy (TMR) 2oo3 voting architecture, providing independent signal replication across three isolated internal links. Built-in self-test (BIST) diagnostic routines achieve a parameter diagnostic coverage of greater than or equal to 99%, isolating physical line faults and component drifts within 10 ms. The integrated 1500 VDC galvanic isolation field physically splits the input circuits from the internal bus structure, executing a continuous fail-safe state strategy that prevents external overvoltage conditions from reaching the logic solver processors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What procedures govern the hot-swapping sequence of the 1600071-001 module?\u003c\/p\u003e\n\u003cp\u003eA: The board architecture supports active online hot-swapping without risking system shutdown. Upon slot insertion, the internal supervisory layers perform diagnostic checks to verify firmware flash compatibility and align signal thresholds prior to integrating the new loop circuitry into the active TMR voting matrix.\u003c\/p\u003e\n\u003cp\u003eQ: How does the interface process alternating digital output and speed frequency pulses?\u003c\/p\u003e\n\u003cp\u003eA: The physical circuit paths are engineered to accept standard 0-24 VDC binary signals or high-frequency pulses from magnetic pickups and proximity probes up to 20 kHz, depending on the specific application termination parameters configured within the software environment.\u003c\/p\u003e\n\u003cp\u003eQ: What are the isolation limitations between adjacent termination loops?\u003c\/p\u003e\n\u003cp\u003eA: The board includes component barriers that provide a minimum of 1500 VDC channel-to-channel and field-to-backplane isolation. This layout prevents cross-talk and ensures that localized field grounding errors remain contained within a single loop terminal block.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the terminal board module into the assigned slot of the Tricon chassis framework, checking that the alignment tracks engage fully without forcing the backplane interface.\u003c\/li\u003e\n\u003cli\u003eTerminate the 24 VDC operating power supply wires at the designated terminals, verifying that the source matches the required +\/-10% voltage tolerance.\u003c\/li\u003e\n\u003cli\u003eFix all low-voltage sensor pulse lines or 24 VDC output conductors into the secure wire ports, checking that all terminal screws are locked down to avoid high-vibration loose contacts.\u003c\/li\u003e\n\u003cli\u003eRoute frequency cables from proximity probes or magnetic pickups through dedicated, isolated wire runs away from high-power AC distribution conduits.\u003c\/li\u003e\n\u003cli\u003eGround the terminal card shield connection directly to the low-impedance copper master instrument ground rail within the protective safety cabinet.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":43712019628122,"sku":"1600071-001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/135_6b8c5a7d-fc6f-43df-bcd8-0dee02fdd80c.jpg?v=1784770477","url":"https:\/\/www.spareoil.com\/products\/1600071-001-triconex-cbyy33001-2-terminal-board-module","provider":"SpareOil Automation","version":"1.0","type":"link"}