{"product_id":"1746-p4-allen-bradley-slc-500-high-capacity-power-supply","title":"1746-P4 Allen-Bradley SLC 500 High Capacity Power Supply","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1746-P4 operates as a high-capacity, chassis-mounted power supply module engineered explicitly for the modular SLC 500 PLC platform, including SLC 5\/02, 5\/03, 5\/04, and 5\/05 processors. This industrial power unit mounts directly on the left side of standard 1746 racks, delivering regulated 5V DC and 24V DC electrical currents straight to the backplane pathways. It provides the necessary power infrastructure to drive hungry processor tasks alongside dense digital and analog I\/O module configurations inside large 7-slot, 10-slot, or 13-slot chassis arrays.\u003c\/p\u003e\n\u003cp\u003eWe supply this product exclusively as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New, original factory-sealed unit\u003c\/strong\u003e, guaranteeing pristine electronic circuit boards, unblemished terminal screws, and optimal chemical lifecycle integrity for the internal capacitors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSLC 500 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1746-P4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original Factory Sealed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModular Chassis Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLine Input Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 to 132 Volts AC \/ 170 to 265 Volts AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLine Input Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTypical Line Power Requirement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 VA to 190 VA at 120V AC \/ 230 VA at 240V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal 5V DC Current Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.0 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal 24V DC Current Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.88 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e24V DC User-Power Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Amp capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e24V DC User Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.4 to 27.6 Volts DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Backplane Power Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 Watts maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Inrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e45 Amps maximum (20 Amps for 8 ms typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDielectric Isolation Barrier\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2600V DC for 1 second\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic current limiting with electronic shutdown\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOver-Voltage Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated electronic shutdown circuitry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFuse Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFactory-included internal non-replaceable soldered fuse\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Wiring Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to two 14 AWG-rated copper wires per screw terminal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Hardware Racks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1746-A7, 1746-A10, 1746-A13 Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14.5 cm x 11.0 cm x 14.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Location Safety\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass I Division 2 Hazardous Locations; UL, CE, CSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Large-Scale Expansion Racks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSmall power modules suffer thermal overload when driving modern electronic cards. The 1746-P4 delivers an expanded 10 Amps of 5V DC current and 2.88 Amps of 24V DC current directly to the backplane, sustaining maximum component density inside 10-slot and 13-slot SLC chassis without requiring external sub-supplies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstand Severe Voltage Fluctuations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnstable factory power grids drop and spike unpredictably. This power supply utilizes a robust transformer and input filter network that accommodates wide voltage tolerances (85 to 132V AC or 170 to 265V AC), preventing automated machinery shutdowns during sudden line sags.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBlock High-Voltage Electrical Surges:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial environments introduce massive noise via inductive motors and switching gear. The 1746-P4 implements a stringent 2600V DC dielectric isolation barrier for 1 second between the primary AC line terminals and the internal DC backplane, keeping high-voltage spikes away from your core CPU memory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplify Live Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe front faceplate displays a clear, green \"Power OK\" LED indicator. This physical diagnostic tool provides immediate visual verification of backplane voltage status, allowing maintenance technicians to separate incoming electrical source failures from downstream processing faults instantly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a lower-capacity 1746-P1 or 1746-P2 supply with this 1746-P4 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1746-P4 offers higher current capacities than the 1746-P1 and 1746-P2 models while maintaining the identical physical footprint and chassis attachment system on the left side of the SLC rack. It provides an ideal upgrade path when adding high-density or analog modules to an existing system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow should I handle an internal fuse failure on the 1746-P4?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1746-P4 features an internal safety fuse soldered directly onto the main power circuit board to prevent fire hazards during catastrophic electrical faults. Because the factory seals this non-replaceable fuse in place, an open fuse typically indicates internal component degradation, requiring a complete module swap to resume safe, reliable operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this power supply require manual jumper configuration for 120V versus 240V AC inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The advanced power regulation circuitry inside the 1746-P4 automatically selects and accommodates the correct incoming line voltage level within the specified 85-132V AC or 170-265V AC operating bands. Always verify your input terminal wiring layout matches the official manual before energizing the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43392146014298,"sku":"1746-P4","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/93_977afd12-6d40-4dfd-bea7-25dc927f6915.jpg?v=1779157692","url":"https:\/\/www.spareoil.com\/products\/1746-p4-allen-bradley-slc-500-high-capacity-power-supply","provider":"SpareOil Automation","version":"1.0","type":"link"}