{"product_id":"1756-pb72-controllogix-24vdc-75w-chassis-power-supply","title":"1756-PB72 ControlLogix 24VDC 75W Chassis Power Supply","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen Bradley 1756-PB72 functions as a high-performance DC-input power supply designed specifically for ControlLogix chassis. This single-slot module installs directly into the standard power supply slot on the left side of the rack, delivering regulated backplane power to drive CPUs, I\/O modules, and communication cards. It sources 100% original, brand-new components to guarantee continuous uptime in demanding process control, automotive manufacturing, and utility automation facilities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1756-PB72 (Series C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18-32V DC (19-32V DC operational range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Input Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Output Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Watts at 0 to 60 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13 A at 5V DC, 2.8 A at 24V DC, 2.8 A at +\/-12V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax. Inrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Isolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Volts (Between power input and backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInsulation Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReinforced Insulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConductor Screw Torque\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.565 Nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +60 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Layout\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOverload, short-circuit, and thermal shutdown\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMitigates Voltage Fluctuations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe wide input range (18-32V DC) protects the control system from heavy machinery voltage drops on the factory floor, ensuring the PLC remains online during DC grid strain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplifies Dense Rack Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe high-efficiency design delivers full 75W output up to 60 degrees Celsius. This prevents localized hot spots in tight, unventilated enclosures and eliminates the need for external cooling fans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminate Ground Loop Noise:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 250V reinforced insulation barriers separate the raw input power lines from the sensitive digital backplane. This stops electromagnetic interference (EMI) from corrupting analog I\/O signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSaves Footprint Space:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact, single-slot mounting mechanism mounts directly to the chassis edge, leaving all standard slots open for operational I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1756-PB72 in a system that requires AC power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This module accepts only DC input voltages (18-32V DC). Connecting this unit to AC mains will damage the internal circuitry. You must use an external AC-to-DC step-down transformer or source an AC-native ControlLogix power supply model instead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this power supply support hot-swapping or redundancy configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1756-PB72 is a standard single-slot power supply. You must power down the chassis completely before replacing or servicing this module. For redundant architectures, choose the 1756-PR2 framework.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wire sizes and installation constraints should I use for safety?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse solid or stranded copper wire rated for the operational temperature environment. Secure the terminal block conductor screws to a torque of exactly 0.565 Nm to prevent loose connections or arcing under heavy industrial vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43403992399962,"sku":"1756-PB72","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/102._5e7c8de6-2eba-4c57-864d-9db44fb2d57b.jpg?v=1779411347","url":"https:\/\/www.spareoil.com\/products\/1756-pb72-controllogix-24vdc-75w-chassis-power-supply","provider":"SpareOil Automation","version":"1.0","type":"link"}