{"product_id":"1762-iq32t-allen-bradley-micrologix-input-module-new-original-stock","title":"1762-IQ32T Allen-Bradley MicroLogix Input Module | New \u0026 Original Stock","description":"\u003ch2\u003eAllen-Bradley 1762-IQ32T MicroLogix Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1762-IQ32T\u003c\/strong\u003e serves as the primary \u003cstrong\u003e1762-IQ32T\u003c\/strong\u003e Input Module utilized to execute 24 VDC digital signal acquisition across MicroLogix platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e1762-IQ32T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.44 lbs (0.20 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e90 mm x 40 mm x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eHandled via expansion bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eInput Channels\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e32 inputs (grouped or isolated from system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eVoltage Range\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e10-30 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eInput Type\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eSinking\/sourcing (dependent on common-pin configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eInput Current\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eApproximately 7 mA per point @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eSignal Delay Time\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003e8 ms maximum (ON-to-OFF and OFF-to-ON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eMounting Options\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eDIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eTerminal Block Type\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eRemovable terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Base Integration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1762-IQ32T\u003c\/strong\u003e coordinates input state transitions with local processing cores which interface with wider factory networks like Profinet \/ EtherNet\/IP deterministic networks. The high-density layout of the 32 discrete sensing channels requires physical signal filtration logic to achieve internal bus stability. Integrated hardware dampening bounds signal delay responses to 8 ms, suppressing contact bounce or electromagnetic field induction while scaling total I\/O density within small modular industrial enclosures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the installation procedures regarding module mapping limits on the internal bus?\u003c\/p\u003e\n\u003cp\u003eA: The module connects via an integrated ribbon cable to the preceding expansion interface. Total system capacity depends on the power supply limitations of the host MicroLogix controller or expansion rack power limits.\u003c\/p\u003e\n\u003cp\u003eQ: How is the sinking or sourcing configuration selected for the 32 input points?\u003c\/p\u003e\n\u003cp\u003eA: Configuration is determined entirely by field-side wiring topology. Connecting the common (COM) terminal to the positive leg of the 24 VDC circuit sets the module channels for sinking execution, while connecting the common terminal to the negative return sets it for sourcing execution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Expansion Connection:\u003c\/strong\u003e Slide the expansion ribbon cable connector securely into the interface slot of the adjacent module. Lock the latch mechanism fully to maintain continuous digital data communication lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Separation:\u003c\/strong\u003e Use the removable terminal block mechanism to perform field maintenance. Ensure the wiring loom is strain-relieved to prevent raw mechanical forces from loosening screw connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Routing Separation:\u003c\/strong\u003e Keep 24 VDC input lines separate from high-frequency or high-voltage AC conductor bundles inside panel raceways to minimize inductive noise transmission into the 7 mA sensor circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Best Practices:\u003c\/strong\u003e Maintain low-resistance contact between the enclosure backing plate and the DIN rail to permit safe dissipation of transient noise spikes through the chassis grounding path.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43415845339226,"sku":"1762-IQ32T","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/163._a8e58447-5d28-43ce-aad1-0ad53ff933a1.jpg?v=1779760436","url":"https:\/\/www.spareoil.com\/products\/1762-iq32t-allen-bradley-micrologix-input-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}