{"product_id":"1769-ia16-rockwell-automation-120v-ac-16-channel-input","title":"1769-IA16 Rockwell Automation 120V AC 16-Channel Input","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1769-IA16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-density AC signal detection for industrial control systems. This module features 16 digital input channels designed to monitor field devices operating on 100\/120V AC power, such as limit switches, push buttons, and motor starter auxiliary contacts. Fully compatible with CompactLogix controllers and MicroLogix 1500 systems, the 1769-IA16 enables seamless integration of AC field signals into your Logix architecture. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware in factory-sealed packaging.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1769-IA16 utilizes robust circuitry to filter industrial noise and provide clean digital transitions to the controller backplane.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1769-IA16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100\/120V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e79–132V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current (Nominal)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 mA @ 120V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Delay (Typical)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 ms to 10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e750V DC (Field side to System side)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 mA @ 5.1V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C (32°F to +140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL, CE, cULus, Class I Div 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1769-IA16 solves common integration hurdles in legacy and modern factory environments where AC control circuits remain standard.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Cabinet Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16 input channels share internally connected commons. This reduces the number of terminal terminations required, allowing for a cleaner and more organized control panel layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module incorporates an inherent 8–10 ms hardware delay. This delay effectively filters out high-frequency transients and contact bounce commonly found in mechanical AC switches, preventing false triggers in the PLC logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Rack Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAt only 35 mm wide, the 1769-IA16 packs 16 AC points into a slim profile. This maximizes the utilization of DIN rail space, especially in retrofits where cabinet volume is limited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemovable Terminal Block (RTB):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated RTB allows for \"pre-wiring\" before module installation. During maintenance, technicians remove the entire block without disconnecting individual wires, which slashes Mean Time to Repair (MTTR) and prevents wiring errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Isolation Barrier:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 750V DC isolation barrier protects the expensive controller CPU and backplane from field-side electrical surges. This ensures the longevity of the entire automation rack even in harsh electrical environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1769-IA16 detect DC signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1769-IA16 specifically monitors AC voltages between 79V and 132V. For 24V DC applications, you must use a DC input module such as the 1769-IB16 or 1769-IQ16.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support individual isolation for each channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1769-IA16 features group isolation. The 16 inputs share common return points. If your application requires point-to-point isolation, you should evaluate specialty isolated modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 1769-IA16 compatible with the 1769-AENTR Ethernet adapter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1769-IA16 functions perfectly in remote I\/O configurations using the 1769-AENTR or 1769-ADN DeviceNet adapters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the Status LEDs on the front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach of the 16 channels has a dedicated LED. These indicators provide an immediate visual diagnostic, allowing maintenance staff to verify field signal presence without using a voltmeter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43166050648154,"sku":"1769-IA16","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/463..jpg?v=1775030571","url":"https:\/\/www.spareoil.com\/products\/1769-ia16-rockwell-automation-120v-ac-16-channel-input","provider":"SpareOil Automation","version":"1.0","type":"link"}