{"product_id":"1771-ibd-allen-bradley-brand-new-10-30vdc-plc-module","title":"1771-IBD Allen-Bradley Brand New 10-30VDC PLC Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1771-IBD functions as a high-density, discrete DC interface card for the Rockwell Automation PLC-5 control platform. This module populates any standard peripheral slot of a 1771 I\/O chassis, converting raw binary (ON\/OFF) signals from field devices into logic-level data for the central processor. Operating across a flexible 10 to 30 VDC voltage span, the 1771-IBD accepts inputs from proximity switches, limit sensors, photoelectric eyes, and selector switches. Control engineers integrate this sinking input module into manufacturing lines, material handling systems, and processing plants to monitor machine states cleanly while keeping field voltage isolated from the backplane.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1771-IBD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital DC Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley PLC-5 Systems and 1771 I\/O Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Restrictions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFits all 1771 frames except legacy 1771-A1, -A2, and -A4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Field Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSixteen (16) independent discrete points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 to 60 VDC maximum absolute span, Sinking (Source Load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC Operating Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 to 30 VDC nominal operating range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Off-State Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 milliamperes allowable leakage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Delay Time (OFF to ON)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 millisecond hardware response filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Delay Time (ON to OFF)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSelectable 1 millisecond or 6 millisecond filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Topology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptical isolation barriers between field loops and backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 milliamperes maximum at 5.0 VDC (plus\/minus 5 percent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Power Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.3 Watts peak thermal output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Power Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Watt internal base state\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Thermal Emission\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24.7 BTU per hour under full load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Keying Position 1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlastic tab slot insertion between pins 10 and 12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Keying Position 2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlastic tab slot insertion between pins 16 and 18\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eField Wiring Arm Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCat. No. 1771-WH or 1771-WN terminal assemblies\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Arm Screw Torque\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 to 9 inch-pounds mounting pressure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Module Mass\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg (1.00 lbs) unpopulated state\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e290 mm x 38 mm x 150 mm (H x W x D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +60 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 degrees Celsius dry ambient\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcurement Supply Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 percent Brand New and Original in Factory Packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch3\u003eFast-Acting 1ms Signal Filtering Captures High-Velocity Transients\u003c\/h3\u003e\n\u003cp\u003eHigh-speed indexing tables, packaging machinery, and sorting conveyors require immediate input tracking to ensure proper mechanical alignment. The 1771-IBD utilizes a low-latency hardware filter that registers input state changes from OFF to ON in just 1 millisecond. This quick-scan capability enables the central PLC-5 processor to capture fleeting sensor pulses instantly, preventing missed parts or timing synchronization drifts that occur with sluggish, commercial-grade input blocks.\u003c\/p\u003e\n\u003ch3\u003eOnboard Optical Barriers Block Field-Side Electrical Surges\u003c\/h3\u003e\n\u003cp\u003eField-side signal loops running through sprawling factories often pass heavy inductive equipment, which couples transient voltage spikes and high-frequency noise into signal lines. The 1771-IBD isolates this noise at the module boundary by embedding high-speed optical isolation circuits. Because light pulses bridge the gap between the field wiring arm and the logic bus instead of copper traces, severe field overvoltages cannot breach the barrier, keeping the 1771 backplane and central processor safe from catastrophic damage.\u003c\/p\u003e\n\u003ch3\u003eDual-Point Plastic Keying Prevents Destructive Card Swapping\u003c\/h3\u003e\n\u003cp\u003eIn crowded marshalling panels housing a mixture of AC and DC signals, a technician could mistakenly slide a low-voltage DC card into a high-voltage AC slot during emergency maintenance. The 1771-IBD neutralizes this danger through dual-point physical backplane keying slots located between pins 10\/12 and pins 16\/18. These molded guides match physical plastic bands inserted onto the chassis backplane, mechanically preventing the 1771-IBD from seating into an incorrectly wired slot.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific wiring arms interface with the 1771-IBD, and how do you install them?\u003c\/p\u003e\n\u003cp\u003eThe 1771-IBD interfaces natively with the 1771-WH or 1771-WN field wiring arms. The wiring arm clips directly onto the chassis frame pivot points in front of the module, meaning you do not disconnect field wires when swapping a card. When securing field wires to the arm terminals, technicians must torque the terminal screws to between 7 and 9 inch-pounds to prevent loose connections or stripped threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this sinking input module handle sourcing (PNP) field sensors directly?\u003c\/p\u003e\n\u003cp\u003eNo. The 1771-IBD features a sinking electrical topology, meaning the input points require a current path to ground to register an ON state. Consequently, you must pair this module with sourcing field devices (such as mechanical dry contacts wired to the positive VDC rail or PNP transistor outputs). Connecting a sinking (NPN) sensor directly to these terminals will prevent the module from sensing the voltage transition cleanly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do you configure the selectable ON-to-OFF input signal delay time?\u003c\/p\u003e\n\u003cp\u003eThe 1771-IBD provides a selectable hardware filter configuration for the ON-to-OFF transition path, allowing technicians to toggle between a fast 1 millisecond response or a dampened 6 millisecond filter. This delay adjustment helps engineers smooth out electrical contact bounce from aging mechanical limit switches. You select the target delay window via internal module jumpers before sliding the card into the active chassis track.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43399674003546,"sku":"1771-IBD","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/252._d5e779f6-e8f5-4f2e-9b0e-38996b315515.jpg?v=1779331401","url":"https:\/\/www.spareoil.com\/products\/1771-ibd-allen-bradley-brand-new-10-30vdc-plc-module","provider":"SpareOil Automation","version":"1.0","type":"link"}