{"product_id":"1771-p6s-rockwell-automation-plc-5-redundant-power-source","title":"1771-P6S Rockwell Automation PLC-5 Redundant Power Source","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1771-P6S operates as a compact, slot-mounted power supply module engineered specifically for the 1771 universal I\/O chassis platform. This hardware module regulates incoming 220V AC municipal line power into clean, stabilized 5V DC backplane current to run high-performance PLC-5 processors and adjacent digital or analog I\/O communication cards. Occupying a single slot inside the standard I\/O rack, it eliminates bulky external standalone power bricks and cuts down panel enclosure wiring complexity. The module natively supports parallel wiring configurations to facilitate automated, redundant power setups in mission-critical manufacturing facilities. We supply this power module exclusively as a 100% brand new, original factory-packaged item to guarantee optimal voltage regulation and maintain maximum lifespan for your processing system.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following engineering matrix sets out the input thresholds, current generation metrics, and physical dimensions for the 1771-P6S module:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1771-P6S\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLC-5 \/ 1771 Universal Chassis Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original Factory Boxed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChassis Slot-Mounted Power Supply Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220 Volts AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e194 to 264 Volts AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Line Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 to 63 Hertz (Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Apparent Input Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e89 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Real Input Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e56 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Transformer Load\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Amperes (8.0 A) continuous at 5 Volts DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Protection Fuse\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 Amperes, 250 Volts, slow-blow safety fuse\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChassis Slot Width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Slot (Installs inside standard I\/O terminal space)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eParallel Supply Cables\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1771-CT interface connector cable bundles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eParallel Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInterfaces with additional 1771-P6S, -LWP, -LZP, -LXP units\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Isolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Volts continuous between input lines and chassis frame\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIntegrated Safeguards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic overvoltage tracking, short-circuit clamp, thermal shutdown\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Ambient Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 degrees C (32 to 140 degrees F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 degrees C (-40 to 185 degrees F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmbient Relative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% Non-condensing environment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg (1.88 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Direct Slot Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module mounts directly into any standard slot within a 1771 universal assembly. This localized installation profile completely gets rid of the long, inductive DC cable leads that are standard with external wall-mounted power bricks, reducing inductive electromagnetic noise pick-up across data traces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault-Tolerant Redundancy Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing standard 1771-CT parallel cabling allows plant electricians to link the 1771-P6S alongside another identical -P6S or -LWP supply module. This dual link constructs an active hot-backup energy system that maintains smooth 5V DC output even if one primary AC line goes down.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTri-Layer Circuit Protection Safeguards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal safety circuits intercept damaging field voltage fluctuations before they can reach the CPU. The overvoltage clamp, short-circuit current limiter, and automatic thermal shutdown system protect expensive downstream memory blocks from electrical stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Efficiency Heat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe specialized mechanical housing uses passive convective venting channels to pull rising ambient air across internal high-temperature capacitors. This ventilation layout ensures the hardware can deliver a full 8 Amp payload continuously at up to 60 degrees C without requiring noisy external enclosure cooling fans.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Ground-Loop Prevention:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA solid 50V continuous isolation barrier isolates incoming raw 220V AC input signals from the sensitive internal logic bus pins. This gap eliminates troublesome plant ground loops caused by uneven potential spikes between main factory substations and localized remote I\/O chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I insert the 1771-P6S power supply module into the left-most dedicated processor slot of a 1771 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. You must install the 1771-P6S power supply within a standard I\/O slot in the universal chassis, not the left-most master controller slot. The processor module (such as a PLC-5\/40) must occupy that master slot, while this power unit slides into an adjacent slot to feed 8 Amps into the backplane power rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of internal replacement fuse does the 1771-P6S require if a power surge trips the unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1771-P6S relies on an internal, field-replaceable 1.5 Amp, 250V slow-blow fuse to manage high-energy input spikes. If an overcurrent event blows this fuse, you must swap it out with an identical electrical component to ensure your industrial circuitry maintains proper overcurrent protection profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1771-P6S module support dual-voltage inputs such as a 120V AC line option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1771-P6S is engineered exclusively for nominal 220V AC operations, with a stable mechanical input tolerance window covering 194 to 264V AC. If your application site provides only 120V AC source loops, you must choose an alternative power module variant from the Allen-Bradley catalog that is rated for that lower voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43387425849434,"sku":"1771-P6S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/58._f836d5d7-78d1-447b-949b-420a581623e5.jpg?v=1779071805","url":"https:\/\/www.spareoil.com\/products\/1771-p6s-rockwell-automation-plc-5-redundant-power-source","provider":"SpareOil Automation","version":"1.0","type":"link"}