{"product_id":"1783-ms06t-allen-bradley-stratix-8000-6-port-managed-switch","title":"1783-MS06T Allen-Bradley Stratix 8000 6-Port Managed Switch","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1783-MS06T functions as a high-performance Layer 2 managed industrial Ethernet switch within the Stratix 8000 network infrastructure family. This network module provides 6 fast copper RJ45 ports that facilitate wire-speed switching, VLAN segmentation, and IGMP snooping directly on the factory floor. Designed to embed seamlessly into modern EtherNet\/IP architectures, the switch utilizes Common Industrial Protocol (CIP) integration to pass real-time diagnostics and status data straight to Logix controllers.\u003c\/p\u003e\n\u003cp\u003eWe deliver this product as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New, original factory-sealed unit in its native factory packing\u003c\/strong\u003e. Each shipment carries a 12-month comprehensive factory warranty, ensuring uncompromised internal circuitry, unblemished connector ports, and authentic embedded firmware ready for secure machine-level deployment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStratix 8000 \/ Stratix 5700 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1783-MS06T\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original Factory Sealed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSwitch Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFully Managed Layer 2 Industrial Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Copper Port Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 x RJ45 Ports (10\/100\/1000 Mbps Auto-Negotiation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Input Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A maximum at 18 to 60V DC, Class 2 \/ SELV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Power Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.1 Watts (Expansion module load excluded)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower and Thermal Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.1 Watts maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Inrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Relay Contact Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 A maximum at 30V DC, Class 2 \/ SELV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Isolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75V continuous (basic insulation type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Boundaries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower to ground, power to network, power to alarm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEthernet Cable Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ45 connector, Category 5e minimum (2 or 4 pair)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower and Alarm Wire Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 to 0.8 mm2 (20 to 18 AWG) solid or stranded copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGround Conductor Wire Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.3 to 5.3 mm2 (12 to 10 AWG) solid or stranded copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Screw Torque\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower and Alarm: 0.23 N-m; Ground: 0.96 N-m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy Protocol Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Level Ring (DLR), RSTP (IEEE 802.1w)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Integration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStudio 5000 Add-On Profile (AOP), CIP Integration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSurrounding Air Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum 60 degrees Celsius (140 degrees Fahrenheit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Enclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone (Open-style industrial module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Location Temperature Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNorth American T4 \/ ATEX T4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamline Control Logic Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard commercial switches require separate external software utilities to monitor port status. The 1783-MS06T utilizes full CIP integration, allowing automation engineers to configure, manage, and retrieve network diagnostics directly inside Studio 5000 Logix Designer using standard Add-On Profiles (AOP).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnforce Zero-Downtime Ring Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCable cuts disable standard star networks instantly. This managed switch executes Device Level Ring (DLR) protocols to create a fault-tolerant network ring, redirecting data traffic within milliseconds if a physical network link suffers damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilter Destructive Multicast Traffic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnmanaged Ethernet networks flood all ports with multicast I\/O traffic, choking downstream devices. The 1783-MS06T activates IGMP snooping to direct multicast data streams strictly to the specific target nodes that request them, optimizing backplane bandwidth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolate Electrical Ground Transients:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial power systems generate heavy voltage spikes and ground shifts. This module implements a 75V continuous basic insulation barrier that separates incoming power channels from the ground framework and network paths, stopping electrical noise before it corrupts communication lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting style does the 1783-MS06T open-style switch require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1783-MS06T features a compact, open-style industrial housing designed for direct installation onto standard 35 mm DIN rails inside a protective, enclosed control panel. Because it carries an open-style rating, you must shield the switch from external liquid spray, dust, and conductive contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do technicians wire the power input and alarm relay terminals safely?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse solid or stranded copper wire rated for 90 degrees Celsius or higher, with a cross-section between 0.5 and 0.8 mm2 (20 to 18 AWG). Strip the wire insulation back a maximum of 1.2 mm, insert the copper leads into the screw terminals, and tighten the terminal screws to a torque specification of exactly 0.23 N-m (2.0 in-lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this switch provide isolation between individual Ethernet ports?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 75V continuous basic insulation separates the main DC power circuit from the ground line, alarm terminals, and the collective network channels. However, the 6 individual RJ45 Ethernet communication ports share a common ground reference, meaning no electrical isolation exists between individual network ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43392155844698,"sku":"1783-MS06T","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/95_0c248898-52fc-4d74-9d14-168192322d4f.jpg?v=1779158307","url":"https:\/\/www.spareoil.com\/products\/1783-ms06t-allen-bradley-stratix-8000-6-port-managed-switch","provider":"SpareOil Automation","version":"1.0","type":"link"}