{"product_id":"1794-adn-allen-bradley-flex-i-o-devicenet-network-adapter","title":"1794-ADN Allen Bradley FLEX I\/O DeviceNet Network Adapter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen Bradley 1794-ADN operates as a high-efficiency network interface and communication adapter module designed explicitly for the modular 1794 FLEX I\/O platform. This hardware component links up to eight individual distributed FLEX I\/O modules directly onto a standard 5-wire DeviceNet industrial network loop, consolidating remote digital, analog, and specialty signals into a single, high-speed deterministic node. Featuring built-in auto-baud rate detection and manual rotary address selection switches, the module bridges field-level signals back to central ControlLogix, CompactLogix, or legacy PLC controllers with minimal system latency. We supply this communication gateway exclusively as a 100% brand-new, original unit to ensure long-term physical fieldbus reliability, full optical noise isolation, and seamless data packet processing in demanding automation cells.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1794 FLEX I-O System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1794-ADN (Series B)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeviceNet Communication Adapter Gateway\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Interface Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard DeviceNet (5-wire configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Data Velocities\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 kbps, 250 kbps, 500 kbps (Auto-Baud Supported)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNode Hardware Addressing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRange 0 to 63 via mechanical onboard rotary switches\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Module Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports up to 8 FLEX I-O modules per single node\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal External Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Volts DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Supply Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.2 to 31.2 Volts DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFLEXBUS Internal Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e640 mA maximum at 5.0 Volts DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Power Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 mA maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum System Power Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.6 Watts maximum at 19.2 Volts DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork-to-Backplane Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull optical isolation (Tested to 50V continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Status Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModule Status (Mod), Network Status (Net), I-O Status LEDs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Field Network Cable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBelden YR-29832 or fully approved DeviceNet equivalent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Stranded Wire Gauge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 AWG stranded copper maximum with 3\/64-inch insulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Spectrum\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +55 degrees Celsius (-4 to +131 degrees Fahrenheit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Mechanical Mounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail or direct protective backpanel surface mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConsolidates and Minimizes Physical Field Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRunning separate home-run sensor cables back to a central control room wastes panel space and increases labor costs. This adapter groups up to eight remote 1794 baseplates into a single field footprint, passing hundreds of discrete signals over one multi-conductor DeviceNet trunk line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplifies Maintenance with Toolless Node Adjustments:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnboard physical rotary switches permit instant, manual hardware addressing from 0 to 63 without requiring an external computer or specialized programming software. This tactile configuration allows plant-floor electricians to replace modules instantly during hardware swaps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBlocks Destructive Field Noise via Optical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-voltage ground loops and industrial electromagnetic interference (EMI) originating on the plant floor can disrupt fragile backplane data streams. The integrated optical isolation layer acts as a safety barrier, stopping electrical transients from breaking through into the internal 1794 system components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccelerates Commissioning via Intelligent Auto-Baud Matching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal network chip scans the active communication trunk line upon system boot to detect the existing clock frequency automatically. This auto-baud routine matches data speeds of 125 kbps, 250 kbps, or 500 kbps instantly, removing configuration steps from network balancing routines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1794-ADN adapter on an industrial EtherNet\/IP network structure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1794-ADN possesses a dedicated transceiving chipset designed only for the DeviceNet network protocol and physical 5-wire cable interfaces. If your facility utilizes or upgrades to an EtherNet\/IP distributed I\/O network topology, you must utilize the corresponding Allen Bradley 1794-AENT network adapter module instead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum number of I\/O modules I can plug into a single 1794-ADN gateway?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis adapter supports a hard physical limit of eight 1794 FLEX I\/O modules hooked together horizontally. The internal 5V DC FLEXBUS provides up to 640 mA of power to drive the internal electronics of these expansion cards, so verify that the total combined current consumption of your eight chosen modules falls within this 640 mA output threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1794-ADN module supply the operational power needed for field-side loop instruments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1794-ADN uses its 24V DC input connection to power its internal processors and provide backplane current to the adjacent expansion modules. You must route an independent, separate 24V DC loop power source through your individual 1794 terminal base units (such as the 1794-TB3) to energize field instruments, proximity switches, and output relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43404077563994,"sku":"1794-ADN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/121._6e1d6262-9429-43d8-a879-8e99e544c0b3.jpg?v=1779418673","url":"https:\/\/www.spareoil.com\/products\/1794-adn-allen-bradley-flex-i-o-devicenet-network-adapter","provider":"SpareOil Automation","version":"1.0","type":"link"}