{"product_id":"1c31161g02-ovation-westinghouse-rtd-sensor-interface","title":"1C31161G02 Ovation \/ Westinghouse RTD Sensor Interface","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson Ovation 1C31161G02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision RTD (Resistance Temperature Detector) Input Personality Module within the Ovation™ Distributed Control System (DCS). This module specializes in acquiring low-level resistance signals from industrial sensors, such as Pt100 and Pt1000, and converting them into accurate digital temperature values for the controller. It provides the necessary excitation current and high-resolution A\/D conversion required for mission-critical thermal monitoring in turbines, boilers, and reactors. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring the measurement integrity needed for stable closed-loop process control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1C31161G02 utilizes advanced signal conditioning to maintain a typical accuracy of ±0.1°C across a wide industrial temperature spectrum.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1C31161G02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD Input \/ Personality Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Isolated Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePt100, Pt1000 (DIN Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–200°C to +850°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14-bit A\/D Conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1°C (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50–60 SPS (Samples Per Second)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;500 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e127 x 33 x 160 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.31 kg – 0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Thermal Acquisition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module manages 16 independent RTD channels within a single Ovation slot. This high-density architecture significantly reduces the physical footprint in control cabinets, making it ideal for balance-of-plant (BOP) systems with extensive sensor arrays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Sensor Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1C31161G02 identifies open-circuit faults and sensor failures instantly. By reporting these diagnostics back to the Ovation HMI, it prevents the controller from executing logic based on \"frozen\" or erroneous data, enhancing overall system safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module effectively filters out 50\/60 Hz line noise and electromagnetic interference (EMI) typical of turbine decks. This ensures that the high-resolution A\/D conversion remains stable, even when sensitive RTD leads run near high-voltage power cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Cold-Junction Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile primarily an RTD interface, this \"Personality Module\" variant handles low-level current signals (±1 mA) and incorporates cold-junction compensation logic. This versatility allows engineers to adapt the module for specialized thermal feedback requirements beyond standard RTDs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStable Excitation Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module delivers a precise, regulated excitation current to the sensors. This eliminates measurement drift caused by fluctuating power supplies, ensuring that your temperature readings remain consistent over years of continuous 24\/7 operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1C31161G02 support 3-wire and 4-wire RTD configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module supports standard industrial RTD wiring configurations to compensate for lead-wire resistance. For the highest accuracy in long-distance runs, we recommend 3-wire or 4-wire setups to ensure the lead resistance does not offset the temperature reading.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for both Pt100 and Pt1000 sensors simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the module hardware supports both types, you must configure the software parameters in the Ovation I\/O Builder to match the specific RTD type connected to each channel to ensure correct scaling and linearization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 50–60 SPS sampling rate benefit my process?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis sampling rate provides a fast update time (under 500ms for all channels), which is essential for \"Sequence of Events\" (SOE) recording and fast-acting thermal protection interlocks in high-speed rotating machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1C31161G02 supports live replacement in an energized Ovation chassis. You can swap the module without powering down the I\/O rack, provided the system configuration and redundancy settings allow for a bumpless transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43136057344090,"sku":"1C31161G02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/370._7a9fdd41-b334-4225-a205-1048f8d5b7fa.jpg?v=1774581065","url":"https:\/\/www.spareoil.com\/products\/1c31161g02-ovation-westinghouse-rtd-sensor-interface","provider":"SpareOil Automation","version":"1.0","type":"link"}