{"product_id":"22-comm-e-allen-bradley-ethernet-ip-adapter-module-new-original-stock","title":"22-COMM-E Allen-Bradley EtherNet\/IP Adapter Module | New \u0026 Original Stock","description":"\u003ch2\u003eAllen-Bradley 22-COMM-E PowerFlex 4-Class Options\u003c\/h2\u003e\n\u003cp\u003eConfigured for Control, Monitoring, and Diagnostics over Ethernet networks, the \u003cstrong\u003eAllen-Bradley 22-COMM-E\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e22-COMM-E\u003c\/strong\u003e EtherNet\/IP Communication Adapter, provides direct physical\/electrical execution for bridging RS485 data paths to EtherNet\/IP communication channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e22-COMM-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 lbs (0.25 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e90 x 45 x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC, approx. 2 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP, Modbus TCP (via bridging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45 (Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps, Full\/Half Duplex, auto-negotiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Addressing\u003c\/td\u003e\n\u003ctd\u003eBOOTP\/DHCP or manual configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eRS485 to EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Type\u003c\/td\u003e\n\u003ctd\u003eSingle or Multi-Drive modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Nodes\u003c\/td\u003e\n\u003ctd\u003eSingle Node architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Drives\u003c\/td\u003e\n\u003ctd\u003ePowerFlex 4, 40, 40M, 40P, 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eInternal Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators\u003c\/td\u003e\n\u003ctd\u003eLED status indicators (Power, Link, Activity, Fault)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drive Integration\u003c\/h3\u003e\n\u003cp\u003eThe 22-COMM-E utilizes dedicated internal bus interfaces to synchronize data transmission with PowerFlex 4-Class internal hardware architectures. The module depends on precise firmware flash compatibility across both the hosting drive processor and the central industrial controller to handle explicit and implicit messaging structures. This interface achieves fast data processing metrics across Profinet \/ EtherNet\/IP deterministic networks, sustaining low communication latencies and reliable I\/O density scaling during multi-drive network mapping configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the physical internal configuration modified when switching from Single to Multi-Drive mode?\u003c\/p\u003e\n\u003cp\u003eA: The configuration mode must be assigned through internal drive parameters via the Human Interface Module (HIM) or software utilities before commissioning. Multi-Drive mode allows one 22-COMM-E adapter to interface with multiple adjacent drives using internal RS485 sequencing protocols, operating under a single IP address node allocation.\u003c\/p\u003e\n\u003cp\u003eQ: What are the restrictions regarding the 1500 V RMS isolation voltage limit?\u003c\/p\u003e\n\u003cp\u003eA: The 1500 V RMS threshold defines the continuous galvanic and transient isolation barrier between the RJ45 network interface and the internal drive circuitry. Exceeding this electrical limit can rupture the internal logic components, causing localized communication loop failures and diagnostic fault errors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Mechanical Mounting\u003c\/strong\u003e: Power down the hosting PowerFlex drive completely and verify that the internal DC bus capacitors have discharged fully before removing the cover. Secure the adapter into its designated slot inside the drive casing using the provided mounting rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Wiring Setup\u003c\/strong\u003e: Connect the category-grade Ethernet cable to the RJ45 port. Avoid routing network infrastructure wires parallel to high-voltage motor output lines or high-frequency power cables to reduce signal crosstalk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP Configuration Routines\u003c\/strong\u003e: Utilize the BOOTP\/DHCP network utility or manual configuration options to allocate a persistent IP address to the module. Ensure the subnet mask matches the main control architecture to enable proper communication mapping via RSLogix 5000 or Studio 5000 environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43420660203610,"sku":"22-COMM-E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/173._75abf646-6bc6-40a6-a8d0-cba2f31dc0a8.jpg?v=1779844492","url":"https:\/\/www.spareoil.com\/products\/22-comm-e-allen-bradley-ethernet-ip-adapter-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}