{"product_id":"24vdc-16-channel-fail-safe-output-card-fc-sdo-1624","title":"24VDC 16-Channel Fail-Safe Output Card | FC-SDO-1624","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-SDO-1624\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-density, fail-safe switching for critical final elements within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Fail-Safe Control (FSC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Manager\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystems. This module features 16 independent 24 VDC channels, allowing the safety controller to manage solenoid valves, emergency shutdown (ESD) relays, and signaling devices from a single rack slot. It converts safety logic into physical actions while maintaining rigorous SIL 3 integrity. We provide this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your safety-instrumented system (SIS) operates with genuine, factory-certified hardware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe FC-SDO-1624 utilizes a robust electrical architecture to ensure rapid response and localized fault containment.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Independent Output Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFail-Safe Digital Output (DO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent per Channel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 1 A (Load dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 3 Capable (IEC 61508)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed safety execution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShort circuit, open circuit, and watchdog monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-system galvanic isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChassis-mounted in FSC\/Safety Manager racks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Cabinet Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy integrating 16 channels into a single module, the FC-SDO-1624 reduces the number of I\/O cards required for large-scale operations. This high-density design lowers overall hardware costs and simplifies cabinet wiring in space-constrained offshore or refinery control rooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProactive Fault Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe onboard diagnostic suite continuously identifies field-side anomalies such as short circuits and line breakages (open circuits). This ensures that the safety loop remains functional and ready to execute a shutdown command when demanded by the process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFail-to-Safe Hardware Watchdog:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn integrated hardware watchdog monitors the internal processor's health. If the module detects an internal logic discrepancy or processor failure, it automatically de-energizes all outputs to their predetermined safe state, preventing uncontrolled process scenarios.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environment Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for an operating range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–40 °C to +70 °C\u003c\/strong\u003e, this module thrives in unconditioned industrial cabinets. It resists the thermal stress associated with outdoor enclosures in extreme climates, ensuring long-term hardware reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the FC-SDO-1624 drive high-current solenoid valves?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Each of the 16 channels supports up to 1 A, which covers most standard industrial solenoid valves and ESD relays. However, always calculate the total rack power budget to ensure the power supply supports the simultaneous activation of multiple loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module signal a field-side fault to the controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module identifies faults through its diagnostic circuitry and communicates these status bits back to the Safety Manager controller. You can then view these alerts via the system software for rapid troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support line monitoring for fire and gas applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FC-SDO-1624 includes built-in diagnostics for open and short circuits, which are essential for monitoring the integrity of safety loops in fire, gas, and emergency shutdown systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or surplus unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. We guarantee that every\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-SDO-1624 is 100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original Honeywell stock. Each module ships in its original factory packaging with a full 12-month warranty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":42870917955674,"sku":"FC-SDO-1624","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/1_f1db42b7-06c5-49f0-aa2a-f3183b79cae3.jpg?v=1776671223","url":"https:\/\/www.spareoil.com\/products\/24vdc-16-channel-fail-safe-output-card-fc-sdo-1624","provider":"SpareOil Automation","version":"1.0","type":"link"}