{"product_id":"24vdc-2a-digital-output-module-honeywell-fc-tsdo-0824c","title":"24VDC 2A Digital Output Module | Honeywell FC-TSDO-0824C","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-TSDO-0824C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-integrity Safe Digital Output module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Manager SC (S300 IOTA)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. This module interfaces the central safety controller with critical field actuators, such as solenoids and emergency shutdown valves (ESV), requiring precise 24VDC control signals. Designed for the most rigorous Safety Instrumented Functions (SIF), it carries a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3 certification\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure process safeguarding in volatile environments. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your safety architecture meets the highest manufacturer and regulatory standards.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-TSDO-0824C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Independent Digital Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 2 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24–30 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL3 (IEC 61508 Compliant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-Channel \u0026amp; Channel-to-System Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (Cabinet Installation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHot-Swap Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240 × 109 × 80 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Drive Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach of the 8 channels supports up to 2 A of switching current. This high-power output allows the module to drive large solenoids and heavy-duty interposing relays directly, often eliminating the need for additional external amplification hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL3 Safety Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-TSDO-0824C executes internal safety protocols and redundant diagnostic checks to meet SIL3 requirements. It ensures that critical final control elements respond correctly during Emergency Shutdown (ESD) or Fire and Gas (F\u0026amp;G) scenarios.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Line Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated diagnostics perform continuous \"Dark Test\" pulses to verify the health of the output circuitry and the field wiring. The module identifies open-circuit and short-circuit conditions immediately, providing real-time feedback to the controller to prevent \"fail-to-danger\" events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust isolation between individual channels and the system backplane prevents electrical noise and surges from migrating through the rack. This protects the CPU and adjacent I\/O modules from field-side interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Climate Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe industrial-grade components withstand operating temperatures from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e–40°C to +85°C\u003c\/strong\u003e. This enables deployment in unheated remote instrument enclosures (RIEs) in extreme geographic locations without risking logic errors or hardware failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Disruptive Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports hot-swapping. Maintenance personnel can replace a faulty unit without powering down the Safety Manager SC or interrupting the execution of other safety-critical loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the FC-TSDO-0824C drive 120VAC solenoids?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The FC-TSDO-0824C provides 24VDC outputs. To control 120VAC or 240VAC loads, you must use the 24VDC signal to trigger a safety-rated interposing relay.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the standard and \"C\" version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"C\" suffix typically denotes a version with specific coating or engineering revisions designed for the S300 IOTA platform, ensuring better protection against corrosive industrial atmospheres and long-term hardware stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle short circuits in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features built-in overload protection. If a field-side short circuit occurs, the diagnostics immediately detect the overcurrent condition, isolate the specific channel, and report a fault to the Safety Manager console.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a 100% Brand New product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell modules. Each unit arrives in factory-sealed packaging to guarantee authenticity and original performance specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43187908313178,"sku":"FC-TSDO-0824C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/405._ff990bb3-1f61-49a5-80d3-b9350bab5b82.jpg?v=1775550565","url":"https:\/\/www.spareoil.com\/products\/24vdc-2a-digital-output-module-honeywell-fc-tsdo-0824c","provider":"SpareOil Automation","version":"1.0","type":"link"}