{"product_id":"2711-k6c16l1-panelview-600-allen-bradley-panelviews","title":"Allen-Bradley 2711-K6C16L1 PanelView 600 Operator Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Allen-Bradley 2711-K6C16L1 is a PanelView 600 operator terminal designed to provide a robust human-machine interface (HMI) for industrial automation systems. This unit features a 5-inch color display and a tactile keypad input, allowing operators to monitor and control machine processes effectively. As a legacy HMI solution, it is frequently utilized to maintain and support existing control architectures, helping to mitigate downtime in established manufacturing and processing environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e5-inch color display for clear visualization of process data.\u003c\/li\u003e\n\u003cli\u003eTactile keypad interface for reliable operator input in industrial settings.\u003c\/li\u003e\n\u003cli\u003eDual RS-232 communication ports for versatile connectivity.\u003c\/li\u003e\n\u003cli\u003eSupports DF1 protocol for seamless integration with SLC 500, PLC-5, and MicroLogix controllers.\u003c\/li\u003e\n\u003cli\u003eDedicated printer\/download port for application management and documentation.\u003c\/li\u003e\n\u003cli\u003eCompact design suitable for panel-mount applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe 2711-K6C16L1 is typically deployed in industrial automation environments requiring serial communication with Allen-Bradley PLC platforms. It is commonly used in manufacturing lines, material handling systems, and process control stations where legacy HMI hardware is required for system compatibility.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-K6C16L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Method\u003c\/td\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Memory\u003c\/td\u003e\n\u003ctd\u003e240 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eRS-232 (DF1) and RS-232 Printer\/Download\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the panel cutout is prepared according to the manufacturer's specifications to maintain the integrity of the enclosure seal.\u003c\/li\u003e\n\u003cli\u003eVerify that the power supply is within the 18-32 VDC range before connecting to the terminal.\u003c\/li\u003e\n\u003cli\u003eUse shielded communication cables for RS-232 connections to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the terminal chassis to the control cabinet ground bus.\u003c\/li\u003e\n\u003cli\u003ePower down the system before inserting or removing any communication cables to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the unit to ensure proper ventilation and prevent overheating.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary communication protocol for this HMI?\u003c\/strong\u003e\u003cbr\u003eThe 2711-K6C16L1 utilizes the DF1 protocol via an RS-232 interface, which is compatible with many legacy Allen-Bradley PLC systems.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this unit be used as a direct replacement for other PanelView 600 models?\u003c\/strong\u003e\u003cbr\u003eReplacement compatibility depends on the specific firmware version and communication requirements of your existing application. Please verify the catalog number and communication settings before installation.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43900751347802,"sku":"2711-K6C16L1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/wm_1_326ba991-84c5-4561-adba-beecf1eec185.jpg?v=1787599921","url":"https:\/\/www.spareoil.com\/products\/2711-k6c16l1-panelview-600-allen-bradley-panelviews","provider":"SpareOil Automation","version":"1.0","type":"link"}