{"product_id":"32-channel-digital-input-module-yokogawa-adv151-e00-s2","title":"32-Channel Digital Input Module YOKOGAWA ADV151-E00 S2","description":"\u003ch2\u003eYOKOGAWA ADV151-E00 S2 Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal acquisition in CENTUM VP distributed control systems, the \u003cstrong\u003eYOKOGAWA ADV151-E00 S2\u003c\/strong\u003e (\u003cstrong\u003eADV151-E00\u003c\/strong\u003e Digital Input Module) provides direct physical and electrical execution of 32-channel status monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADV151-E00 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndonesia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e107.5 mm x 130 mm x 32.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard cabinet environmental specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.4 A at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e32 Isolated Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2 kV AC (System to Input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and DCS Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe ADV151-E00 maintains signal integrity across the 32 discrete inputs through advanced channel-to-channel isolation architecture. This design prevents transient electrical noise or ground loops on individual field circuits from propagating back to the control processor. The module interfaces seamlessly with existing DCS backplanes, supporting HART-compliant loop monitoring where applicable. By implementing optical coupling, the module ensures that the digital state transitions remain deterministic under high-interference conditions. Accurate processing of 24 VDC levels is sustained through consistent threshold voltage verification, ensuring that the 3 ms response time is maintained across all operational channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ADV151-E00 support hot-swapping while the controller is powered? A: Yes, the module supports hot-swapping in non-redundant and redundant configurations, provided the associated field wiring is properly managed to prevent accidental short-circuits during module extraction.\u003c\/p\u003e\n\u003cp\u003eQ: How should the redundancy be configured for this module? A: For dual-redundant operation, two ADV151-E00 modules must be installed in adjacent, system-designated slots. The controller software will automatically handle the synchronization and failover logic between the two modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the field input voltage does not exceed the rated 26.4 VDC to prevent damage to the opto-isolators.\u003c\/li\u003e\n\u003cli\u003eEnsure the module locking levers are fully seated to guarantee secure contact with the backplane bus pins.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded twisted-pair cabling for all field signal runs to minimize EMI, ensuring the shield drain is grounded at the cabinet entry point only.\u003c\/li\u003e\n\u003cli\u003eVerify channel mapping in the engineering station database following physical installation to ensure accurate point-to-tag correlation.\u003c\/li\u003e\n\u003cli\u003eIf utilizing a cable adapter, confirm the interface cable is fully latched to the module faceplate to maintain structural stability.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43577318899802,"sku":"ADV151-E00 S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/177._6a3ca0bd-e86e-4c36-a551-3e88f46642ad.jpg?v=1782885247","url":"https:\/\/www.spareoil.com\/products\/32-channel-digital-input-module-yokogawa-adv151-e00-s2","provider":"SpareOil Automation","version":"1.0","type":"link"}