{"product_id":"32-point-transistor-contact-output-module-yokogawa-adm52c-s2","title":"32-Point Transistor Contact Output Module | Yokogawa ADM52C-S2","description":"\u003ch2\u003eYokogawa ADM52C-S2 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ADM52C-S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eADM52C\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for discrete signal switching and pulse generation within Yokogawa DCS networks. The module provides 32 discrete transistor contact output channels, executing switching functions up to 30 VDC at 100 mA per point. Programmable output logic supports continuous states alongside pulse duration timing ranging from 0.1 to 7200 seconds.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-S\u003c\/td\u003e\n\u003ctd\u003eStandard Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eStyle 2 Hardware Revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eADM52C-S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg (0.31 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm x 107.5 mm x 32.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e600 mA max at 5.0 VDC (Backplane bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e32 discrete output points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Type\u003c\/td\u003e\n\u003ctd\u003eTransistor contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 VDC, 100 mA (resistive\/inductive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Range\u003c\/td\u003e\n\u003ctd\u003eAdjustable from 0.1 to 7200 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (channel-to-system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe ADM52C-S2 module resides alongside process I\/O cards executing 4-20 mA HART loop protocol communications within CENTUM VP cabinet nodes. High-density galvanic isolation barrier circuits separate internal backplane logic from external field contact loops. This isolation suppresses ground loops and electrical switching transients, preserving measurement integrity across adjacent analog input channels and preventing thermal reference drift on cold junction compensation (CJC) circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power rail supplies the ADM52C-S2 module logic circuit?\u003c\/p\u003e\n\u003cp\u003eA: The module draws power directly from the 5.0 VDC backplane bus, consuming a maximum current of 600 mA.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle inductive loads connected to its transistor outputs?\u003c\/p\u003e\n\u003cp\u003eA: The solid-state transistor contacts are rated for up to 30 VDC and 100 mA for both resistive and inductive field loads.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInsert the ADM52C-S2 into an available slot on the Field I\/O (FIO) node base unit. Tighten top and bottom retaining screws to ensure stable mechanical grounding and backplane interface contact.\u003c\/p\u003e\n\u003cp\u003eRoute field contact cabling through separate wire ducts away from high-voltage AC power lines. Connect external 24 VDC \/ 30 VDC field power sources through fused terminal blocks to protect output transistors from direct short-circuit conditions. Connect cable shield drains directly to the cabinet single-point earth ground lug to mitigate electromagnetic noise coupling.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43831940382810,"sku":"ADM52C-S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/207_6d1fe2b1-4e6d-4f35-a536-f0bf4e3669c3.jpg?v=1786500772","url":"https:\/\/www.spareoil.com\/products\/32-point-transistor-contact-output-module-yokogawa-adm52c-s2","provider":"SpareOil Automation","version":"1.0","type":"link"}