{"product_id":"32100-hima-relay-amplifier-module-new-original-stock","title":"32100 HIMA Relay Amplifier Module | New \u0026 Original Stock","description":"\u003ch2\u003eHIMA 32100 Relay Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA 32100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e32100\u003c\/strong\u003e Relay Module, operates as a dedicated hardware component for signal amplification and relay switching within safety-instrumented systems (SIS).\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e32100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eRelay Module (Dual-Channel Amplifier)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ 24 V=\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 6 A at 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2 independent relay channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Configuration\u003c\/td\u003e\n\u003ctd\u003e1-signal with pre-logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard terminal housing footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg (Shipping Weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSIL3 Certification and Fail-Safe State Execution\u003c\/h3\u003e\n\u003cp\u003eThe 32100 dual-channel relay amplifier module conforms to rigorous functional safety requirements to sustain SIL3 certification conditions depending on system architecture. The physical assembly incorporates absolute galvanic isolation to separate the low-voltage logic signal inputs from the heavy-current relay contacts. Operating primarily via the de-energize-to-trip protocol, any loss of the nominal 24 VDC supply voltage or pre-logic input signal triggers a fast fail-safe state execution, causing the output contacts to drop open in less than 10 ms to isolate the associated field-level final control elements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What action does the 32100 module perform if a logic processing fault occurs in the pre-logic stage?\u003c\/p\u003e\n\u003cp\u003eA: Any fault detected in the internal logic or input stage overrides the command latch, resulting in an immediate fail-safe state execution where both independent relay output channels are forced into their de-energized open state.\u003c\/p\u003e\n\u003cp\u003eQ: Is online hot-swapping supported for the 32100 relay module on a standard DIN rail?\u003c\/p\u003e\n\u003cp\u003eA: No. Field connections must be completely de-energized and isolated before attempting physical module removal or replacement on the DIN rail to avoid voltage transients and contact arcing.\u003c\/p\u003e\n\u003cp\u003eQ: What is the recommended technical inspection schedule for the internal mechanical contacts of the 32100?\u003c\/p\u003e\n\u003cp\u003eA: To verify safety loop availability, the mechanical relay contacts require systematic physical testing and contact resistance inspection every 12 to 18 months.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Assembly Stability:\u003c\/strong\u003e Snap the terminal base firmly onto a standard top-hat DIN rail. Verify that the mechanical locking mechanism is completely engaged to prevent module slippage under environmental vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Line Grounding Constraints:\u003c\/strong\u003e Install all discrete loop control lines using independent shielded runs. Connect the screens exclusively to the central low-impedance safety instrumented ground plane to isolate the logic from parasitic currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Load Suppression:\u003c\/strong\u003e When driving inductive field devices such as heavy-duty solenoids or valve coils, wire external surge suppression networks in parallel with the load to mitigate high inductive flyback voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Sizing and Torquing:\u003c\/strong\u003e Terminate field connections with correctly sized wire gauges. Ensure screw terminals are tightened to specified torque boundaries to prevent high-resistance contact points.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43426150121562,"sku":"32100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/274._2643b13d-963f-4830-b0c7-5f9906a79fe8.jpg?v=1779938530","url":"https:\/\/www.spareoil.com\/products\/32100-hima-relay-amplifier-module-new-original-stock","provider":"SpareOil Automation","version":"1.0","type":"link"}