{"product_id":"330104-00-20-10-01-cn-bently-nevada-3300-xl-8-mm-proximity-probes","title":"330104-00-20-10-01-CN Bently Nevada 3300 XL 8 mm Proximity Probes","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330104-00-20-10-01-CN\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330104\u003c\/strong\u003e Proximity Probe, operates as a dedicated hardware component for non-contacting displacement and vibration measurements within 3300 XL Proximity Transducer System platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330104\u003c\/strong\u003e: Base model number for 3300 XL 8 mm proximity probe with M10 x 1 threads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded Length Option (00 = 0 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-20\u003c\/strong\u003e: Overall Case Length Option (20 = 200 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10\u003c\/strong\u003e: Total Length Option (10 = 1.0 meter \/ 3.3 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e: Connector and Cable-Type Option (01 = Miniature coaxial ClickLoc connector with connector protector, standard cable).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-CN\u003c\/strong\u003e: Agency Approval Option (CN = Country-specific Hazardous Area Approval).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-00-20-10-01-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.323 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8 mm probe tip diameter, 200 mm case length, 1.0 m total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C (-60 deg F to +351 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 mA maximum (driven by external Proximitor Sensor at -17.5 VDC to -26 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe 330104 probe interfaces directly with a matching extension cable and 3300 XL Proximitor Sensor to establish an eddy-current path optimized for rotor dynamics tracking. Proper system tuning depends on precise eddy-current probe scaling to convert target proximity into a linear output sensitivity of 7.87 V\/mm (200 mV\/mil). During structural machine loop configuration, field technicians perform gap voltage validation using designated -10 VDC targets to ensure operation remains centered within the linear displacement envelope. Maintaining exact installation clearance is critical for cross-talk suppression when multiple measurement tracks are positioned on the same rotor shaft, effectively dampening overlapping magnetic fluxes that could alter static position or dynamic vibration readings.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the \"01\" connector protector option alter physical handling in the field?\u003c\/p\u003e\n\u003cp\u003eA: The integrated connector protector physically prevents the ClickLoc coaxial connection from touching the surrounding machinery housing or conduit walls. This layout ensures electrical isolation and mitigates grounding faults without requiring manual tape wrap or field sleeves.\u003c\/p\u003e\n\u003cp\u003eQ: What are the deployment consequences of a mismatch between a 1.0-meter probe and a 5.0-meter system?\u003c\/p\u003e\n\u003cp\u003eA: The 330104-00-20-10-01-CN probe has a total electrical length of 1.0 meter, which requires a matching 4.0-meter extension cable to complete a standard 5.0-meter system loop. Pairing this probe with an incorrect cable length alters the overall line impedance and completely compromises factory calibration metrics.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting Torques\u003c\/strong\u003e: Thread the M10 x 1 stainless steel probe case into position. Do not exceed the maximum rated installation limit of 33.9 N-m (300 in-lbf) for forward-mount configurations to avoid permanent structural distortion of the casing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Voltage Verification\u003c\/strong\u003e: Supply the loop with proper operating voltage (-17.5 VDC to -26 VDC) from the Proximitor. Rotate the probe until a digital multimeter records the calibrated -10 VDC target across the output terminal, confirming correct linear center gap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Cable Bend Radius Constraints\u003c\/strong\u003e: Ensure all routed coaxial sections adhere strictly to a minimum physical bend radius of 25.4 mm (1.0 inch). Kinking or straining the cable permanently alters core electrical parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Isolation Compliance\u003c\/strong\u003e: Under the -CN country-specific certified framework, ensure all physical probe terminations pass through approved explosion-proof junction boxes or intrinsic safety barriers before integrating with external machinery protection racks.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43603961053274,"sku":"330104-00-20-10-01-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330101-37-57-10-02-051_b53e5cae-dd37-4c96-8088-115676b3744e.png?v=1783324004","url":"https:\/\/www.spareoil.com\/products\/330104-00-20-10-01-cn-bently-nevada-3300-xl-8-mm-proximity-probes","provider":"SpareOil Automation","version":"1.0","type":"link"}