{"product_id":"330880-16-00-075-00-02-bently-nevada-proxpac-xl-transducer-assembly","title":"330880-16-00-075-00-02 Bently Nevada PROXPAC XL Transducer Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330880-16-00-075-00-02\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330880\u003c\/strong\u003e PROxPAC XL Proximity Transducer, operates as a dedicated hardware component for direct physical vibration and shaft position acquisition within 3300 XL monitoring networks. The field-mounted assembly houses an integrated probe element designed to deliver continuous proximity signal conversion for rotating equipment diagnostics.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe and Approvals Option\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe without approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandoff Adapter Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Penetration Option\u003c\/td\u003e\n\u003ctd\u003e075\u003c\/td\u003e\n\u003ctd\u003e7.5 in penetration depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFittings Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo fittings: two plugs and two washers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330880-16-00-075-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNet Weight: 1.44 kg, Shipping Weight: 3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.5 in penetration depth, 3\/4-14 NPT mounting connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +177 deg C (probe tip operational range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive transducer (powered via external Proximitor Sensor loop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm proximity probe assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Equivalent\u003c\/td\u003e\n\u003ctd\u003eDirect field replacement for model 330880-28-35-036-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe PROxPAC XL housing converts mechanical shaft displacement into proportional eddy-current signal alterations across the 3300 XL 8 mm sensing element. Accurate rotor dynamics measurement relies on maintaining proper eddy-current probe scaling to ensure linear voltage output across dynamic position changes.\u003c\/p\u003e\n\u003cp\u003eDuring installation and field setup, technicians perform gap voltage validation (-10 VDC targets) using test terminals at the connected Proximitor module to establish the probe at the linear midpoint. High cross-talk suppression guarantees signal integrity when probe heads are mounted in close physical proximity on turbomachinery bearing housings.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 330880-16-00-075-00-02 directly replace an older 330880-28-35-036-00-02 unit?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 330880-16-00-075-00-02 is a designated manufacturer functional replacement for the 330880-28-35-036-00-02 assembly.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting interface is required on the machine housing for this transducer?\u003c\/p\u003e\n\u003cp\u003eA: The housing incorporates a standard 3\/4-14 NPT threaded connection for mounting directly into the machine port or mating mounting boss.\u003c\/p\u003e\n\u003cp\u003eQ: How is the probe element powered?\u003c\/p\u003e\n\u003cp\u003eA: The transducer tip functions as a passive inductive sensing element and receives high-frequency RF excitation directly from an interconnected 3300 XL Proximitor sensor.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInspect thread surfaces and engage the 3\/4-14 NPT mounting fitting cleanly into the port, achieving standard NPT thread engagement (typically 5 turns hand-tight plus wrench torque) without over-stressing the outer housing.\u003c\/li\u003e\n\u003cli\u003eVerify probe gap positioning using a digital multimeter across test terminals to perform gap voltage validation (-10 VDC targets) prior to securing the housing lock mechanisms.\u003c\/li\u003e\n\u003cli\u003eCheck that internal terminal seals, plugs, and sealing washers are installed correctly to maintain environmental housing integrity against fluid penetration.\u003c\/li\u003e\n\u003cli\u003eRoute coaxial cable runs through grounded protective conduit, avoiding sharp bend radii and isolating signal cabling from high-voltage AC motor wiring.\u003c\/li\u003e\n\u003cli\u003eConnect coaxial cable shielding continuously to the monitoring rack system ground, leaving the probe housing isolated at the machine boundary to prevent ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":43816584740954,"sku":"330880-16-00-075-00-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/330880-28-40-058-01-02_24b5e8e7-d2da-41a1-b948-761dfb385c86.png?v=1786331532","url":"https:\/\/www.spareoil.com\/products\/330880-16-00-075-00-02-bently-nevada-proxpac-xl-transducer-assembly","provider":"SpareOil Automation","version":"1.0","type":"link"}