{"product_id":"3500-05-01-02-00-00-01-bently-nevada-3500-series-rack-chassis","title":"3500\/05 Bently Nevada Rack Chassis | New \u0026 Original Stock","description":"\u003ch1\u003eBently Nevada 3500\/05 3500 Series Rack Chassis\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/05-01-02-00-00-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3500\/05\u003c\/strong\u003e System Rack Chassis, operates as a dedicated hardware component for mechanical housing, power distribution, and backplane bus connection within the 3500 Series Machinery Protection System. This 14-slot physical frame provides mechanical structural support and electrical signal paths for data interchange among multi-channel monitoring modules. Designed with a standard 19-inch panel mount form factor, it secures specific physical alignments and shielding integrity for the integrated instrumentation.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe specific structural and approval configuration for the full part number 3500\/05-01-02-00-00-01 is defined by the fixed hardware options below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01 (Rack Size Option):\u003c\/strong\u003e 19-inch Standard Rack providing 14 available functional module slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02 (Mounting Option):\u003c\/strong\u003e Panel Mount configuration designed for securing onto rectangular panel cutouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00 (System Faceplate Option):\u003c\/strong\u003e Standard faceplate without specialized custom branding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00 (Data Communications Option):\u003c\/strong\u003e Standard physical backplane routing without specialized network bridges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00 (Reserved Option):\u003c\/strong\u003e No designated hardware modifications applied.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01 (Agency Approval Option):\u003c\/strong\u003e CSA\/NRTL\/C certification for Class 1, Division 2 environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e3500\/05-01-02-00-00-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e4.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e48.26 x 34.92 x 26.59 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003ePassive chassis backplane distribution; active consumption determined by installed power supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eChassis Material\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eIndustrial-grade aluminum and steel alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eAvailable Slots\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e14 functional instrument slots plus dedicated power supply positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eWiring Interconnect\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eRear-access termination paths for I\/O modules and primary power sources\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eEnvironmental Limits\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/05 backplane is designed to transfer physical sensor inputs across the data bus without attenuation or distortion. When paired with proximity monitor modules, the chassis internal layout preserves accurate eddy-current probe scaling coefficients across all 14 communication nodes. Proper structural grounding inside the panel-mounted frame prevents cross-talk suppression failures when transmitting variable gap voltage metrics. This electrical isolation maintains the precise -10 VDC target alignment required to trace micro-inch mechanical displacement during rotor dynamics analysis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 3500\/05 rack chassis power supply slots operate in a hot-swap or redundant configuration?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The chassis infrastructure contains independent routing paths allowing the installation of dual redundant power supply modules. A failed power supply unit can be replaced while the chassis remains energized without interrupting the signal validation or backplane communication of the active monitor modules.\u003c\/p\u003e\n\u003cp\u003eQ: What mitigation measures are engineered into the chassis backplane against signal cross-talk?\u003c\/p\u003e\n\u003cp\u003eA: The backplane utilizes internal copper ground planes interleaved between signal traces. This layer stacking acts as a continuous Faraday cage to enforce cross-talk suppression between high-frequency proximity transducer signals and lower-speed serial bus data lines.\u003c\/p\u003e\n\u003cp\u003eQ: What are the restrictions regarding the physical positioning of monitoring modules within the 14 functional slots?\u003c\/p\u003e\n\u003cp\u003eA: Slot 1 is structurally reserved for the 3500\/15 Transient Data Interface module. Slots 2 through 14 can house any combination of standard 3500 Series monitors and I\/O modules, provided total current draw does not exceed backplane power rails limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Cutout Alignment:\u003c\/strong\u003e Verify the rectangular panel cutout matches the 48.26 cm by 26.59 cm mounting window. Ensure all surrounding sheet metal is deburred prior to inserting the chassis frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding:\u003c\/strong\u003e The panel mount installation requires a low-impedance ground wire connection from the dedicated ground stud on the rear housing directly to the main plant earth ground grid.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Clearance:\u003c\/strong\u003e Provide at least 20 cm of clearance behind the rear panel plane to satisfy bending radius limits for multi-conductor cables and to permit access to terminal blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Maintain free vertical space around the enclosure to prevent restriction of passive airflow through the chassis vents, keeping ambient temperatures within the -30 to +65 deg C operational window.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870904684634,"sku":"3500 05-01-02-05-00-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/93_bc13f4c1-1606-47e0-b835-2c1cba7214c4.jpg?v=1770953994","url":"https:\/\/www.spareoil.com\/products\/3500-05-01-02-00-00-01-bently-nevada-3500-series-rack-chassis","provider":"SpareOil Automation","version":"1.0","type":"link"}