{"product_id":"3500-15-01-01-00-machinery-protection-system-ac-power-pim","title":"3500\/15-01-01-00 Machinery Protection System AC Power PIM","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/15-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the essential power conversion interface for the 3500 Series Machinery Protection System. This Low Voltage AC Power Input Module (PIM) accepts facility-level alternating current and transforms it into the stabilized DC rails required to drive vibration, position, and speed monitoring cards. Its universal input design eliminates the need for jumpers or voltage switches, making it a versatile solution for global industrial deployments. We supply this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your critical asset protection system remains powered by genuine, high-specification hardware.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: 3500\/15-AA-BB-CC-DD\u003c\/h3\u003e\n\u003cp\u003eThe configuration for the 3500\/15-01-01-00 indicates a standard universal AC setup:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01 (AA)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow Voltage AC (85 to 264 V AC RMS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e01 (BB)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow Voltage AC (Redundant or Single)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00 (CC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo Approvals (Standard Configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00 (DD)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExpansion Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/15-01-01-00 utilizes advanced switching technology to maintain high efficiency and minimal thermal discharge.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage (Nominal)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110V to 220V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage (Range)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85V to 264V AC RMS (Universal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40A @ 120VAC \/ 80A @ 240VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2500V DC (Input to Backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 °C to +65 °C (-22 °F to +150 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e251.5 mm x 50.8 mm x 120.7 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeak Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e373V AC Peak\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Voltage Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module handles a broad input range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e85V to 264V AC\u003c\/strong\u003e. This flexibility allows engineers to specify the same part number for facilities worldwide, simplifying spare parts inventory and reducing engineering design time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing high-efficiency power conversion, the 3500\/15-01-01-00 reduces heat buildup within the rack. This preserves the accuracy of adjacent high-precision vibration monitors and extends the overall mean time between failures (MTBF) for the entire system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis PIM supports dual-power supply configurations. In a redundant setup, the system maintains full machinery protection even if one AC source fails or a single power module malfunctions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Dielectric Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2500V DC isolation protects the sensitive backplane electronics from field-side electrical transients and surges, preventing catastrophic system failure during power fluctuations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 3500\/15-01-01-00 require manual voltage switching for 110V or 220V?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module features a universal input circuit that automatically adjusts to any AC voltage within the 85V to 264V RMS range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a high-voltage AC module with this low-voltage version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must ensure your facility power matches the module's input requirements. If your supply is within the 85-264VAC range, this module is the correct choice. Always verify the rear Power Input Module (PIM) matches the front Power Supply module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"00\" agency approval code?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"00\" code indicates a standard unit without specific hazardous area certifications (like ATEX or Class I Div 2). If your installation environment requires specific explosion-proof ratings, please consult our technical team for the appropriate dash code.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Bently Nevada unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We provide the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15-01-01-00 in 100% Brand New condition\u003c\/strong\u003e, shipped in original factory packaging with full traceability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42870888169562,"sku":"3500\/15-01-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/375.jpg?v=1776670021","url":"https:\/\/www.spareoil.com\/products\/3500-15-01-01-00-machinery-protection-system-ac-power-pim","provider":"SpareOil Automation","version":"1.0","type":"link"}